Question
Answer
What is the part number for the E996L rim conversion kit?
Resolution:
The 050672 is the part number for rim or vertical rod device and 050673 for the mortise device.:
What cylinder is used in the Falcon 24/25 exit alarm kit?
Resolution:
The Exit Alarm takes a 1 1/8" Mortise cylinder with a straight cam. See first page of Exit Alarm inst below. Exit Alarm inst:
What is the part number for the EAK PCB only for Monarch Falcon devices?
Resolution:
This circuit board will NOT work on the updated 24/25 Alarm Kits that released June 11th, 2012.:
What is the current draw of a Von Duprin exit alarm kit ALK?
Resolution:
The current draw of a Von Duprin exit alarm ALK is .25 amp when alarm is activated.:
Does a Von Duprin ALK kit come with an RX switch?
Resolution:
ALK kit comes with standard RX switch. It can be ordered without the RX switch or with LX switch as an option.:
The Von Duprin 98 or 99 ALK kit will not sound the horn
Resolution:
Followings are the reason for 98/99 exit alarm ALK not sound when push bar is activated. Make sure key switch on exit alarm ALK is turned on, wait for 20 seconds before you activating the pushba...:
If using the alarm kit-ALK with the 99 device what power supply is needed?
Resolution:
Exit alarm ALK operates with 9VDC battery and doesn't required a power supply.If you choose to hard wire the exit alarm ALK use the PS902 power supply.Exit alarm ALK requires 24VDC regulated power ...:
Can a Von Duprin 996L trim be converted to E996L trim?
Resolution:
A E996 conversion kit is required to convert the 996L/L-BE trim to E996L/L-BE electric trim. 050672-00 is the electric conversion kit for 996L rim or vertical rod exit device. 050673-00 is the ...:
Is there a conversion kit to electrify the LP373L lever control?
Resolution:
There is not a conversion kit to electrify the LP373L lever control. You need to order a complete E-LP373L-BE control through Engineering Specials.:
Can Von Duprin GBK's be stacked up to clear a 9/16" glass bead on a fire door?
Resolution:
You can only use one GBK Glass Bead Kit (1/4") per device on fire rated openings. Glass Bead Kit is for use on doors with raised glass beads.:
What are the Von Duprin part numbers for RX, LX and RX,LX-LC switch kits for field installation?
Resolution:
The attached table shows the part numbers for LX-RX and LX-RX-LC switches field installed.:
Are the Pushbar Retrofit Kits (PBKIT) the same for 98/99 and 33A/35A series devices?
Resolution:
A PBKIT is a Pushbar Retrofit Kit.The pushbar retrofit kits are not the same for 33A/35A and 98/99 series exit devices. Depending on the finish of the exit device, the pushbar end caps are di...:
Do we have conversion instructions for the E996 when shipping conversion kits?
Resolution:
We ship the standard installation instructions because it contains enough information to show how to convert the trim from mechanical to electrical.: