AL entry lock for xray door

RELATED FAQS

Question
Answer
AL-Series and discontinued D Lever-Series locks use castle nuts to hold the chassis to the spring cages and to keep the chassis positioned in the door. This causes confusion at times when the lock ...
The easiest method to obtain an AL lock for a 2" door is to specify a 2" thick door when ordering.  
Part required by function:2 each A700-043 driver & A700-034** lever insert in addition to the chassis parts below:AL10S – 2 hubs A700-028AL25D – 2 hubs 1 A700-028 (inside), 1 A700-030 (outside)...
Schlage offers the AL170 single dummy trim, but for applications where a double dummy is needed you can install two AL170 dummy trims back-to-back.  Each AL170 is shipped with a threaded rod (part ...
The AL series lock fits up to 1 7/8” door thickness out of box.
The standard door range for an AL lock is 1 3/8" to 1 7/8".  Using the supplied instruction sheet, align the springcage post to desired door thickness by adjusting the outside castle nut. See inst...
Apartment Corridor Lock function is defined as a lock where the latch bolt operated by lever from either side, except when outside lever is made inoperative by a stop or mechanical means other than...
Changes to the Falcon W501 latch offering were made on 2/13/2012.   Prior to 2/13/2012: The W501 entry lock was supplied with a restoring latch which causes the button to pop and unlock...
“Cache Mode” is an AD-Series feature which, accumulates and stores valid credentials that have recently been granted access by the Access Panel or head-in system. This recently granted access histo...
The number of bits selected for "Card Bit Format" on an AD400 or AD300 must be equal too or larger than the bits on the cards in use. Setting this number correctly enables the cache mode collectio...
The AD300 and AD400 devices do not store audits during cache mode.  Audit "Date and Time" information and the saving of audit information is an Access Control Panel function, and during cache mode ...
An AD400 granting credentials access in “cache mode” will blink the Schlage with the normal green LED, followed by a brief red Schlage LED flash, indicating no RF communication and access was grant...
This change was implemented in firmware package CO.A.6 (or later) to help the customer in the communication and coupling process between the CO200 (CO250) and the hand held device (HHD). ...
The green LED is to be lit up until the spindle (Triangles and Key Switch) are aligned properly; providing a visual indication of the problem.  
If the mechanical alignment of the triangles on the back of the outside escutcheon are not aligned, the CO200 or CO250 will not connect with the SUS/HHD and will appear to be unresponsive...
In firmware CO.A.6 (or later) the Schlage button on the CO200 (CO250) will turn green anytime that the spindle triangles on the front escutcheon are out of alignment or the mechanical key switch is...
When unlocking the CO200 door by mechanical key override, the green led will be continuously ON until the key is released. This will occur after firmware CO.A.6 (or later) has been installed int...