Can Von Duprin QEL/EL and CX be in the same device?

You can not use these options together on the same device per the following reasons:

  1. QEL/EL device retracts the latch bolt of the exit device allowing entry.
  2. CX (Chexit) device locks the push bar of the exit device which causes the delayed egress.
  3. CX device doesn't retract the latch bolt.
  4. The Chexit solenoid or motor occupies the same space that the EL solenoid or QEL motor would occupy.

For applications that need both delayed egress and latch retraction, consider getting an EL or QEL device with an RX-LC switch to trigger a DE5300 Delayed Egress Controller which would control when a Schlage Electronics M400 Series Maglock (recommend the P option, for example the M490P) is securing the door.

Please contact the Exits Technical Product Support Group to discuss further at 877-671-7011, select option 2 in the first menu for Product Support, then option 3 in the second menu for Exits.


DISCLAIMER:

INFORMATION PROVIDED THROUGH THIS SITE IS PROVIDED TO YOU AS IS WITHOUT ANY EXPRESS REPRESENTATIONS OR WARRANTIES OF ANY KIND, AND WE MAKE NO REPRESENTATION OR WARRANTY THAT THIS SITE(OR ANY INFORMATION PROVIDED IN RESPONSE TO YOUR INQUIRY), WILL BE ACCURATE, COMPLETE, OR ERROR-FREE.

YOU AGREE THAT YOU MUST EVALUATE ALL INFORMATION AND RESPONSES, AND THAT YOU BEAR ALL RISKS ASSOCIATED WITH, THE USE OF THIS SITE, INCLUDING ANY RELIANCE ON THE ACCURACY,COMPLETENESS, OR USEFULNESS OF ANY INFORMATION OR MATERIALS MADE AVAILABLE THROUGH THIS SITE.