Which strike do you use with an XP98/99 device?
Solution ID
55879
Resolution
The 909 strike is used in single and paired non-fire rated and single fire rated openings. The 954 strike is used in fire rated paired openings.
The 1609 strike cannot be used with Von Duprin XP98/99 exit device.
Notes
When ordering mullions for use with pairs of XP98/99 devices, order the mullion "Blank" to get no holes prepped for other strikes.
909 strike can be used for rated or non rated single or pair doors and the 954 strike can be used with Fire rated pairs with a mullion.