Solution ID

127686

Resolution

Auto-unlock periods DO NOT (NEVER) over-ride an emergency "Lockdown"

A CO220 Safe School lock that has been placed into it's Lockdown mode using the paired Fob, will not permit pre-programmed Auto-Unlock periods or Holiday Passage Schedules to allow access. 

The CO200 will remain in it's lockdown mode even if/when a schedule is pre-programmed to allow access.

Only a credential with the  Pass-Through function, can gain temporary access through a CO220 Safe School lock that is in it's lockdown mode, all other credential types are denied.