For delayed egress products greater than 15 seconds, who grants approval and who needs proof of the approval?
The IBC says, “Where approved, a delay of not more than 30 seconds is permitted on a delayed egress door.”  Over 15 second delay requires approval (not necessarily a letter) from the aut...
Schlage Commercial » Building Code
Is the Falcon F-25-C device hurricane rated?
The F-25-C (fire rated version only) device is hurricane impact rated.  Reference Florida Building Code FL12400.     See this article for more information: &nbs...
Schlage Commercial » Exit Devices | Schlage Commercial » Exit Devices » Touch Bar » 25 Series » Falcon | Schlage Commercial » Building Code
Are Ives hinges UL fire listed, and do they bear a UL fire label marking?
UL labeling is not required for hinges used in fire rated assemblies provided they meet the requirements of Section 6.4.3 of NFPA 80-2022 - Standards for Fire Doors and Other Opening Protectives. ...
Schlage Commercial » Ives | Schlage Commercial » Building Code
Can the M996L trim be used with the 2SI option?
Yes, the M996L trim can be used with the 2SI (security indicator) option. NOTE:  In the case that M996L is set for fail safe, the 2SI option can mechanically lock the trim and prevent ingr...
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » Building Code
Does the 385A strike meet ADA standards?
Accessibility standards note 0.5" diameter max allowable openings in floor surfaces. The 385A does require a larger opening for the strike to work with the devices as tested for proper operation...
Schlage Commercial » Von Duprin | Schlage Commercial » Building Code