The 22, 33/35A and 98/99 rim exit devices:
The 6111 is the most common electric strike to be used with these devices
6112 and 6113 electric strikes also could be used
The 6300 surface mount el...
This is not a recommended application as the electric strike does not have the same holding force as the XP98/99 rim exit device. The electric strike has 1500 pounds of holding force whereas the XP...
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F, 8875-F or...