Von duprin guard x

RELATED FAQS

Question
Answer
The following are part numbers for 2670 Guard X exit device PCB: pcb.10018 for English pcb.10019 for Spanish pcb.10020 for French
The Von Duprin Guard-X exit device is not fire rated because the deadbolt is not spring loaded. Therefore, there would be no positive latching as required on a fire rated opening. 
Von Duprin does not offer any lever trim or pulls that through bolt to the Guard X device.  Ives has the 8102-6 and 8105-6 pulls that can be lined up with the mounting screws of the exit device b...
Replacing the battery on the 2670 should not cause the unit stop working. Make sure the spring that provides tension on the plastic finger is not bent out. The spring should be at a 90 degrees...
The 2670 Guard X uses a standard rim cylinder for either push side or pull side.  The rim cylinder can be installed to the outside of the opening with an offset pull to operate the 2670 Guard X d...
The 2670 Guard X device can't be cut down to fit doors less than 3 feet.  This device is designed to fit doors 36"-48" door width.
The Von Duprin 2670 Guard X does not have a spring loaded latch bolt, it is a dead bolt and will not operate with any electric strikes.
Exit devices are not designed for exterior application. If used in an exterior applications then a powder coated finish on the 33/35 and 98/99 series are recommended for exterior applications. ...