senior swing inrush

RELATED FAQS

Question
Answer
The 9542, 9553, 9563 surface mounted Senior Swing with a regular arm, mounted on the push side of the door, can handle a reveal from 1 1/8" up to 10". The 9542, 9553, 9563 surface mounted Senior S...
The 4600 is designed for an opening with (MOSTLY) manual traffic, and the (OCCASIONAL) automatic activation. The Senior Swing is designed for an opening with (MOSTLY) automatic activation, and (OC...
The 8310-877 Bodyguard Safety Sensor attaches (plugs in) to the P1 connector on the Senior Swing controller. The 8310-846 (761462-00) wiring harness "included" with the 8310-877 safety sensor is us...
An electric strike or maglock (24 volt only) can be wired to a Senior Swing 2800/9500 series operator using the P10 Lock Interface cable. To power the 24VDC electric strike or maglock off a LCN Se...
To convert a 9530 to an 9540 you need to purchase the 9540-3077 REG push arm assembly. To convert a 9540 to an 9530 you need to purchase the 9530-3077 PLCM pull arm/track assembly.
Surface Mounting - A 9542 DD (double door) header and a 9540-18 mounting plate can be used on the active leaf. A manual closer with a PA (parallel arm) can the be installed on the inactive leaf.  B...
When installing the arm; the gearbox shaft and door must be at the (+90°) full open position. The following step are used to install the Senior Swing (STD) pull arm. Install the header using app...
When installing the arm; the gearbox shaft  and door must be at the (+90°) full open position. The following step are used to install the Sr. Swing (REG) push arm. Install the header and door brac...
First, turn off the power to the Senior Swing. If the door closes, check controller for a constant activation signal from an activation device. If door continues to hang up and will not close...