What is the backset for a 98/99 rim device with a 1609 strike?
Resolution:
The backset for a 98/99 rim PANIC device with 1609 strike is 2 3/8" from center of the opening to center line of the device. See template :
Is the Von Duprin 1609 strike fire rated for pairs of doors?
Resolution:
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...:
What cylinder is used for the Von Duprin -2 double cylinder function?
Resolution:
The 98/99 rim device can be converted to double cylinder 98-2 or 99-2.Double cylinder features an inside key cylinder which locks or unlocks the outside trim (Classroom Function) and an&n...:
Can you add double cylinder to an existing 99 rim device?
Resolution:
The 98/99 rim device can be converted to double cylinder 98-2 or 99-2. Double cylinder features an inside key cylinder which locks or unlocks the outside trim (Classroom Function) and an outside...: