LCN senior swing minimum door opening

RELATED FAQS

Question
Answer
The minimum door widths for mounting a Senior Swing are: Concealed 2810 Series: 2811 single door (offset pivot or butt hinge) -- 33". 2811 single door with stop (center pivot) -- 36". 2853 pa...
"PUSH SIDE" application: Minimum 52" wide pair, with neither door being less than 21" wide. "PULL SIDE" application: Minimum 60" wide pair, with neither door being less than 30" wide.
The older model Senior Swing came with 2 spring options. The "standard force" spring required 15 lbs of manual  opening force, and reduced force "RF" required 11 lbs of manual opening force.  All S...
Here is an updated list of errors shown on keypad display of the Senior Swing control: Er04 - Voltage Monitor was high during Opening hardware check. Er05 - Master or slave CPU has oscillator ...
When installing the arm; the gearbox shaft  and door must be at the (+90°) full open position. The following step are used to install the Sr. Swing (REG) push arm. Install the header and door brac...
When installing the arm; the gearbox shaft and door must be at the (+90°) full open position. The following step are used to install the Senior Swing (STD) pull arm. Install the header using app...
First, turn off the power to the Senior Swing. If the door closes, check controller for a constant activation signal from an activation device. If door continues to hang up and will not close...
The 9542, 9553, 9563 surface mounted Senior Swing with a regular arm, mounted on the push side of the door, can handle a reveal from 1 1/8" up to 10". The 9542, 9553, 9563 surface mounted Senior S...
The Senior Swing operator is designed to power open the door to 90°. The built in dead stop (in the gearbox) prevents it from opening any further. If the Senior Swing operator is opening to far (pa...