glynn johnson weight

RELATED FAQS

Question
Answer
Consider the Soss hinge like a butt hinge to determine the size of overhead that is needed.  For templating use the same mounting group as a 4" wide butt hinge and the appropriate door thickness.
The maximum recommended door weight for LCN closers is 225 lbs.
Butt hinges can be used on  doors up to 4' wide and 200 pounds.  There is no maximum door height, just need to add a hinge for every 30" or part there of over 7'.
A 4040-18G drop plate will be needed to drop the closer and arm down far enough not to conflict with the GJ 90 series overhead stop.
The basic units are similar.  The ADJ has a 12" long track that is mounted in the frame to allow the degree of opening to be selected in the field anywhere from 85 to 110 degrees, where the standar...
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.
There is not a conflict between the 4041/4040XP EDA door closer and the GJ 100 or 410 overhead concealed series stops.  The exception is:  the 4041/4040XP mounted on a drop plate, and the Glynn Jo...
ST Number Product 1 Product 2 Description ST-2776 4040XP Rw/62A Overhead stop 81, 90, 100, 410, 450 series The standard P...
A special template is not needed, the closer drops down far enough on the door where it does not conflict with the GJ100 series concealed overhead stop. 
ST-2730 is used with a 4110 closer and GJ90 series (up to size 4).  ST-2730 includes a special template and special arm with a -62G shoe and bent forearm. If a drop plate is required, a 4010-18 d...
The LCN 4041/4040XP and the Glynn Johnson 90 series can be mounted in conjunction with each other without a special template.  The 4040 door closer is on the pull side of the door and the GJ 90 is ...
Please see  Glynn-Johnson and Ives Care and Maintenance instructionsOnce the link opens there will be an attachment to "click" on.
It would be unnecessary to use the CNS/Cush arm and the Glynn Johnson overhead devices in the same application, both mechanisms stop the door.
Special template ST-2211 is used to mount a 2030 series closer with a GJ 70,79,81,90, and 450 series overhead stops. This ST works with any GJ "surface" mounted stop. The 2030 closer cannot b...
The 4640 will have to be mounted to the flush ceiling template.
The AA is now the Ives CL11, the BB is now the Ives CL12 and the AP2 is now the CL14.
The Ives version is the same as old Glynn-Johnson versions.