door closer for extreme wind conditions

RELATED FAQS

Question
Answer
Regular LCN closers have "3" regulating valves for General Speed, Latch Speed, and Backcheck. If the LCN closer has "4" regulating valves, then the closer has the Delayed Action feature. De...
A 4110 with AVB (advance variable back check) would be recommended. Using a SCUSH (Spring Cush) arm will also help minimize shock to all door hardware.
To correctly answer this question, we need to know how much more force is required to get the door closed. They could try turning the Rod & Shoe over (short side of shoe towards the hinge), or they...
The LCN closer fluid "Liquid X" will perform without variation between:  -30° F to +120° F - for manual closers.  +35° F to +120° F - for electrical closers and automatic operators. At around ...