coupling mode with laptop

RELATED FAQS

Question
Answer
If the error "Device does not support this action - E802" appears when trying to couple the lock, it is generally because the user is not pressing the SW1 tamper button 3 times, but instead pressin...
In order to properly couple, the interior pushbutton must be held down while tapping the SW1 (tamper switch) three times.  This will enable the lock to couple to the HHD.
Yes, several HHD's can be used with a single lock, as long as the HHD's have the same Coupling Password as the lock.
The HHD coupling password is set during the lock initialization, coupling process.
When the coupling password is changed the value is stored in the HHD and once coupled to a lock, the Coupling Password is also loaded in the lock/device memory.
The Coupling Password is compared whenever an HHD is trying to adjust lock configuration settings or downloading door programming files.
Once a user changes the SUS coupling password , the previous SUS coupling password is also saved by the SUS program; this allows the user to update multiple locks with a new Coupling Password witho...
The Coupling Password update is automatic; whenever the Schlage Utility Software, with a new Coupling Password connects with a device, the Schlage Utility Software will automatically update its old...
The internal process to couple a device with new SUS password is described as follows: the SUS first tries to couple with the current password.  If that fails, the SUS tries to couple with the prev...
To verify that the device/lock is coupled; click on the SUS device options-> Couple HHD to device , a message will pop up confirming that the device is already coupled.  
After updating the SUS coupling password, subsequent HHD’s will need the new coupling password entered before they can update any information in the lock, once the HHD has the correct coupling pass...
Remove the PIM400/401 cover. Connect the HHD to the PIM using the HH-USB cable. The PIM400/401 will be displayed on the HHD screen. On the HHD, select Device Options, On the PIM400/401, press and h...
You can also follow the proper procedure by linking to the Schlage Utility Software User Guide document on page 19 Couple HHD to PIM.
If the PIM400 has already been coupled with a HHD, the Coupling process will be disabled and the PIM400 will no longer go into its Coupling Mode.  You must RESET the PIM400 in order to allow (re-en...