co lock door stile

RELATED FAQS

Question
Answer
The coin cell Nuisance Delay on CO200 and CO250 can be temporarily disabled using the Schlage Utility Software.
Once disabled via the SUS application, the CO lock will no longer delay the access for valid credentials.
If your CO lock began indicating a low coin cell (Nuisance Delay) after a door file has been downloaded, the coin cell is low and should be replaced. (CR2032)The coin cell Nuisance Delay will be "A...
The coin cell Nuisance Delay settings in the SUS application is not available until such time that a Door file is successfully downloaded to the lockset.
The coin cell is ignored when the lock sets are used with Manual Programming ONLY or while in Construction mode.
The AD and CO locks both have a 3 hour fire door rating. Please see URL for more info.  UL Fire Rating List
The minimum stile for each lock will depend on the backset and the rose diameter/escutcheon width.  See the Schlage Minimum Stile Guidelines  for the minimum stile for each...
The minimum recommended Stile measurement is 5” to allow proper mounting of the AD and CO series locks.
Depending on the door construction the minimum stile may differ but a safe dimension would be 4-3/4".  CUSTOMER must check door construction. The pocket depth requirements of the case is 4 1/2".