cm light codes
”
RELATED FAQS
Question
Answer
Why does the Schlage button light up “Green” when I open the door?
Resolution:
When unlocking the CO200 door by mechanical key override, the green led will be continuously ON until the key is released. This will occur after firmware CO.A.6 (or later) has been installed int...:
CM Lock Manual Programming Disabled
Resolution:
When trying to program a CM lock, it may display an error code with a solid green light and 10 read flashes. This indicates the lock has already been programmed with computer software and manual ...:
Does the ID3D HandKey and HandPunch have a red/green verification light like the F-Series?
Resolution:
Yes, the ID3D does have a red/green LED light option. It's used to indicate successful (green) or rejected (red) hand reads. The part number is GL-100 and it can only be installed in th...:
What is the maximum glass light size on a 3 hour (180 minute) fire rated door?
Resolution:
Maximum glass light sizes for 3 hour fire doors is as follows: Wire glass - not approved for use in 3 hour fire doors. Ceramic glass: UL & ITS/WH allow one (1) light with 100 square inc...:
What is the maximum glass light size on a 90 min (1 1/2 hour) fire rated door?
Resolution:
Standard listed wire glass: one (1) light with 100 in2 per door leaf max.Firelite or other appropriately listed glass:• FM maintains one (1) light with 100 in2 per door leaf max.• UL &...:
What is the maximum size of a welded elevation frame?
Resolution:
The following size limitations per frame unit, are in enforced for welded elevation frames shipped from the factory. These limitations are in place due to the physical size of shipping tr...:
What is the rough opening in walls for frame installations?
Resolution:
For DW, K three sided frames and four sided borrowed light frames: Three sided frame = door opening width (order size) plus 1 1/2" minimum to 2" maximum and the door opening hei...:
What is exposed glass size?
Resolution:
When dealing with glass lights in doors, there are three (3) critical dimensions which must be coordinated: Exposed Glass Size (EGS) - the horizontal and/or vertical dimensional size of the vision...:
What is the minimum dimension from the edge of the door to a glass light cutout?
Resolution:
Minimum dimensions to cutouts for glass lights: Vertical edge of door to edge of cutout = 5 29/32" Top of door to top of cutout = 6" Bottom of door to bottom of cutout = 10" Reinforcing chann...: