What size wire is required to operate the Von Duprin EL exit device?

Minimum wire gauge requirement for Von Duprin electric latch retraction is as follows:

For Product Shipped Prior to August 2012 using the old (black) potted module:

  • 0-100 ft 14 gauge wire
  • 0-200 ft 12 gauge wire

For Product Shipped After August 2012 using the new PWM (clear):

For EL 98/99 or 33A/35A Rim Devices

  • 0-500 ft 12 Gauge Wire
  • 0-300 ft 14 Gauge Wire
  • 0-200 ft 16 Gauge Wire
For all other 98/99 or 33A/35A device types

  • 0-250 ft 12 Gauge Wire
  • 0-150 ft 14 Gauge Wire
  • 0-100 ft 16 Gauge Wire