Will the 900-FA board drop power to the entire power supply?
Only if connected to a PS-902.  If using a separate option board to connect the 900-FA to a PS-904, 906, or 914 then it will only drop the power to the option board it is mounted onto....
Schlage Commercial » System Components » Power Supplies
Is the 593PI-12DC 120 VAC to 12 VDC Power Supply UL listed?
It is just a plug in transformer, so it is not UL Listed....
Schlage Commercial » System Components | Schlage Commercial » System Components » Power Supplies
Locknetics LP150/250 Power Supplies - Wiring in Fire Alarm
Wire the Fire Alarm panel back to the “Control In” terminals on the Power Supply.  It needs to be a Normally-Closed dry contact from the Fire Alarm. ...
Schlage Commercial » System Components » Power Supplies
Schlage Handkey II (HKII) Power Supply Information
The reader requires a 12-24VDC power source. The unit can use either a 12 or 24VDC signal from an external power supply, or a plug-in power supply: PS-110 for 110VAC facilities. PS-...
Schlage Commercial » Biometrics » HandKey | Schlage Commercial » System Components » Power Supplies
Is QELA compatible with the PS873 power supply?
QELA is compatible with the PS873.  ...
Schlage Commercial » System Components » Power Supplies | Schlage Commercial » System Components » Power Supplies » PS900 Series
Are the standoffs replaceable on the PS900 series power supplies?
The standoffs or mounting posts for mounting circuit boards are a very tight press fit.  They should not loosen.  If the standoffs have loosened or are missing, they can not be put back in p...
Schlage Commercial » Power Supplies | Schlage Commercial » Power Supplies » Standard | Schlage Commercial » Power Supplies » Standard » PS900 Series | Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin | Schlage Commercial » System Components » Power Supplies | Schlage Commercial » System Components » Power Supplies » PS900 Series | Schlage Commercial » System Components » Power Supplies » PS900 Series » Schlage Electronics
If you are using a 2RS, 4R or 4RL board in a PS902, should the DC out +/- on the board still have power on them?
Yes, the main DC out of PS902 will have constant power out unless there is a 900-FA board on the main board and the FA board is active in a fire alarm state....
Schlage Commercial » Power Supplies | Schlage Commercial » Power Supplies » Standard » PS900 Series | Schlage Commercial » System Components » Power Supplies