What mag lock replaced the former Von Duprin 700?
There is not a direct replacement for the old Von Duprin 700 Shear Lock series mag lock.The Von Duprin 700 had been replaced by the old Locknetics 280-700, which has also since been discontinued, and ...
Schlage Commercial » System Components » Electromagnetic Locks » 280+ Series | Schlage Commercial » System Components » Electromagnetic Locks » 280+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » GF3000 Series | Schlage Commercial » System Components » Electromagnetic Locks » GF3000 Series » Schlage Electronics | Schlage Commercial » Von Duprin
Do the magnetic locks take AC voltage?
Do magnetic locks take AC voltage?No, maglocks only take 12 or 24 volts DC from a filtered and regulated power supply, generally at less than 1 amp @ 12vdc, and .5 amp @ 24vdc.(See the installation or...
Schlage Commercial » System Components » Electromagnetic Locks | Schlage Commercial » System Components » Electromagnetic Locks » 101+ Series | Schlage Commercial » System Components » Electromagnetic Locks » 101+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 280+ Series | Schlage Commercial » System Components » Electromagnetic Locks » 280+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 320+ Series | Schlage Commercial » System Components » Electromagnetic Locks » 320+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 320M | Schlage Commercial » System Components » Electromagnetic Locks » 320M » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 350+ Series | Schlage Commercial » System Components » Electromagnetic Locks » 350+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390+ Series | Schlage Commercial » System Components » Electromagnetic Locks » 390+ Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 390DEL Series | Schlage Commercial » System Components » Electromagnetic Locks » 390DEL Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 40 Series | Schlage Commercial » System Components » Electromagnetic Locks » 40 Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » 70 Series | Schlage Commercial » System Components » Electromagnetic Locks » 70 Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » GF3000 Series | Schlage Commercial » System Components » Electromagnetic Locks » GF3000 Series » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » M390RFK | Schlage Commercial » System Components » Electromagnetic Locks » M390RFK » Schlage Electronics | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series | Schlage Commercial » System Components » Electromagnetic Locks » M400 Series » Schlage Electronics
GF3000 wiring color differences
See attached:GF3000 Standard:GF3000 BRD ...
Schlage Commercial » System Components » Electromagnetic Locks » GF3000 Series | Schlage Commercial » System Components » Electromagnetic Locks » GF3000 Series » Schlage Electronics
Can the current versions of GF3000 Shear Locks be mounted vertically?
No, the current version of the GF3000 has the coil fixed without springs and cannot be mounted vertically.  Older versions had springs which would allow vertical installs. ...
Schlage Commercial » System Components » Electromagnetic Locks » GF3000 Series
Can the GF3000 be installed on wood door and wood frame?
It can be installed on Wood Frame, but Wood Door is not recommended....
Schlage Commercial » System Components » Electromagnetic Locks | Schlage Commercial » System Components » Electromagnetic Locks » GF3000 Series
GF3000 - On the armature there is a thin strip of aluminum that flexes. Is that available as a separate part # or only as part of the armature?
Not available as a separate part. It is part of the armature. ...
Schlage Commercial » System Components » Electromagnetic Locks » GF3000 Series
What is the resistance reading of the coil on a GF3000 Mag lock?
The coil should read 14 ohms between the white and red wires at the coil....
Schlage Commercial » System Components » Electromagnetic Locks » GF3000 Series
Getting 24vdc input to GF3000 Control Module but lock not energizing
Lock will only energized when magnet coil assembly is mated to armature and is correctly aligned....
Schlage Commercial » System Components » Electromagnetic Locks » GF3000 Series
GF3000 won’t lock has 12 or 24v at the mag lock inputs.
·        Make sure the gaping is correct between the armature and mag lock 1/8 inch   ·        Also, armature needs to be...
Schlage Commercial » System Components » Electromagnetic Locks » GF3000 Series
What replaced the 290 maglock?
The 290 was a surface mounted shear lock. So at this point, the replacement (not same size) would be the GF3000SM. GF3000SM is slightly bigger in size...
Schlage Commercial » System Components » Electromagnetic Locks | Schlage Commercial » System Components » Electromagnetic Locks » GF3000 Series