Does the Von Duprin 6300 electric strike require a large cutout?
No cutout is required for mounting the 6300 electric strike with the exception of a small hole for routing the wires....
Schlage Commercial » System Components » Electric Strikes » 6300 Series » Von Duprin
Does Von Duprin have a repair department?
Von Duprin and Falcon do not offer repair services for any of its exit devices....
Schlage Commercial » Exit Devices » Cross Bar » 55 Series » Von Duprin | Schlage Commercial » Exit Devices » Cross Bar » 88 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 22 Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 33A/35A Series » Von Duprin | Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » Power Supplies » Standard » PS900 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 4000 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 5100 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 6300 Series » Von Duprin
Is there a monitor switch for the 6300 electric strike?
There are no optional monitor switches available for the 6300 electric strike....
Schlage Commercial » System Components » Electric Strikes » 6300 Series » Von Duprin
Can a DPS switch and two 6300 strikes be ran off a PS902?
DPS switch is not a load and is not a factor in sizing the Power Supply.  The PS902 will power two 6300 electric strikes no problem....
Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 6300 Series » Von Duprin
What electric strikes can be used with the Von Duprin aluminum mullions?
Aluminum mullions 5654 or 5754 are not designed to accept any electric strike including 6300 surface mounted electric strike....
Schlage Commercial » Exit Devices » Mechanical Accessories » Mullion » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 6300 Series » Von Duprin
Can the 6300 electric strike be Fail Safe?
The Von Duprin 6300 surface mounted electric strike is only available as Fail-Secure....
Schlage Commercial » System Components » Electric Strikes » 6300 Series » Von Duprin
Where can Von Duprin 6300 electric strike installation instructions or templates be found?
Von Duprin surface mounted 6300 electric strike paper template and installation instruction are provided with the electric strike. See attached https://us.allegion.com/c...
Schlage Commercial » System Components » Electric Strikes » 6300 Series » Von Duprin
What electric strike can be used with the XP98/99 devices?
This application is not recommended as elelctric strikes have never been tested with XP98/99 exit device because it would defeat the XP device holding force purpose.  ...
Schlage Commercial » Exit Devices » Touch Bar » 98/99 Series » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 6300 Series » Von Duprin
How can the Von Duprin 4854 mullion be ordered when using the 6300 electric strike?
...
Schlage Commercial » Exit Devices » Mechanical Accessories » Mullion » Von Duprin | Schlage Commercial » System Components » Electric Strikes » 6300 Series » Von Duprin
What is the amount of pre-load force allowed for the 6300 electric strike before the strike will no longer release and operate properly.