Why is there a transient voltage suppressor included with my electric strike?
ANSI BHMA 156.13 has a provision for inductive kickback.  Using the transient suppressor across the strike's solenoid wires allows this standard to be met.  This would be most applicable if ...
Schlage Commercial » System Components » Electric Strikes | Schlage Commercial » System Components » Electric Strikes » 6000 Series | Schlage Commercial » System Components » Electric Strikes » 6000 Series » Von Duprin
I have a customer who needs to replace a Folger Adams electric strike, model #310-2 fail secure 24V.
For a single door, use  6215.For a  double door, use 6226. ...
Schlage Commercial » System Components » Electric Strikes
For 6221 open back electric strike in a wood door, is the maximum door thickness 1 3/4" ?
6211  can be used on a 2 1/4" door also.  The strike would  need to offset to the pull side, instead of center of the door.  ...
Schlage Commercial » System Components » Electric Strikes
Does the Von Duprin 6211 mount at the standard 3/8" ANSI offset above the mortise lock face for the Von Duprin 7500 mortise lock?
Yes, the 6211 mounts 3/8" above the Von Duprin 7500 mortise lock face centerline, but NOT for the majority of other mortise lock manufacturers.  ...
Schlage Commercial » System Components » Electric Strikes
Can I use the Von Duprin 5100 electric strike for mortise locks?
Can I use the Von Duprin 5100 electric strike for mortise locks?   No, the 5100 electric strike is NOT intended for mortise locks, only cylindrical locks (like the Schlage ND 80).  ...
Schlage Commercial » System Components » Electric Strikes
Does Von Duprin carry an electric strike for pairs of doors with the typical ANSI 4 7/8" edge prep?
Does Von Duprin carry an electric strike for pairs of doors with the typical ANSI 4 7/8" edge prep?   NO, Von Duprin does NOT carry an electric strike for pairs of doors with a 4 7/8" edge p...
Schlage Commercial » System Components » Electric Strikes
Can the 6400 be used with a Rim exit device?
The 6400 electric strikes are used with the mortise and cylindrical lock sets....
Schlage Commercial » System Components » Electric Strikes
What 6000 series electric strike will replace the Von Duprin 5100 ?
What 6000 series electric strike will replace the Von Duprin 5100?  The 6211 is our preferred replacement for the 5100....
Schlage Commercial » System Components » Electric Strikes
Are there other solenoids available besides the 12/24 volts DC for the Von Duprin 6000 series electric strikes?
Are there other solenoids available besides the 12/24 volts DC solenoids for the Von Duprin 6000 series electric strikes?Yes, Von Duprin also sells a 16 volts DC and 28 volts DC solenoid for use in th...
Schlage Commercial » System Components » Electric Strikes
What is the part number for mounting tabs for electric strikes?
We do not offer mounting tabs for 6000 series electric strikes.  However, the mounting tabs found in PKGMTG.1004 for the 5100 series mounting package could be used.  The frame or door...
Schlage Commercial » System Components » Electric Strikes