windload label frame

RELATED FAQS

Question
Answer
Dutch doors are available as Fire Rated door assemblies and have similar component requirements as a single leaf fire door. Exceptions are as follows: The Dutch Door assembly must have a lock...
The 2010 and 2030 closer are not the same. The 2010 Series closer uses the (larger) 4010 cylinder which requires a 4" minimum frame tube to mount in. The 2030 uses the (narrow) "Pacer" cylinder...
The UBC (Uniform Building Code) was a regional legacy building code which was superseded in most jurisdictions by the IBC (International Building Code). There may be some areas of the country which...
Fire labels (UL, ITS/WHI or FM) are located as follows: Butt Hinges and Pivots: On the doors the fire label is located on the hinge edge between the top and 2nd hinge preparation. On the fram...
UL, WH, FM
Yes, Steelcraft doors and/or frames are available and can carry a UL, WH or FM label. The type of fire label (UL, WH or FM) is dictated by the specifications and local building code. Doors ...
Drywall Slip-on Frame is an industry term describing a 3 sided frame designed to be installed on a wall composed of steel or wood studs with gypsum board or other facing material and is i...
Maximum hourly rating for a transom and side light or panel frame is 1 1/2 hour (90 minutes). In masonry wall application the maximum is 13'6" x 12'2" In stud wall application the maximum is 13...
The following are quantities of EMA anchors (pierce and dimples) based on range of frame height:  Quantity  Nominal Frame Height     2     1'...
266M is on all Von Duprin exit devices and does not identify the device.
Monorail cutouts are typically the upper corner of door. Channels are cut to size welded into door held flush to cutout. We do not supply any covers or plates to finish.
The size monorail cutout is 8" wide x 24" high
Monorail cutouts are only available for non fire rated applications.
The new QEL motor has a label affixed to the cover, the older QEL motor has no such label.  See attached image.
The part number depends on the handing and finish of the device:  RHR, US28 is #4270107321  LHR, US28 is #4270107323  RHR, DC13/DC35 is #4270107320  LHR, DC13/DC35 is #4270107322.
A Dutch Door is a door having two separate leaves, hung one over the other: Usually equipped so that both leaves can be operated Usually in single doors applications but sometimes specified ...
The 4011 and 4021 use the same closer body but other components are different. The 4011 mounts "pull" side. When ordered as a 4011, it comes with a 6-3/8" rod and shoe, pull side instruction...
The UL fire label is only applied to the device center case cover at the factory when the device is built.  This label can not be sold or replaced with a new one.
The 8402 kick plate is "A" label for metal doors and "B" for wood doors.
The 20 minute Fire Rating is a valid label and are commonly referred to as "Smoke and Draft control door assemblies". Depending on the local fire code and the openings's applica...
The Special Von Duprin 2' door device as of 02-07-14 is now shipped with UL Panic Hardware label or UL Fire Exit Hardware label.  The 2’ devices are most commonly used in 5...
UL, WH, FM
Steelcraft have tested different types of doors and frame assemblies using Zero International gasket seals for the various STC ratings. Tests are in accordance to ASTM...
Frames can be installed either KD (knock down) or welded to receive the STC rating.
Steelcraft borrowed light frames are not listed/tested. Check with the glass manufacture if they are listed and with what type of framing used.
Sound seals are required. Zero International Gasket Notes: Perimeter Seals – Zero #475 applies to the stop of the head and jambs. Door bottom – Zero #367, surface applied. Threshold ...
DW-Series Fire Rated Borrowed Lights are available in the following sizes: 60 minute (1 hour) rating = 2721 square inches of visible glass. maximum frame rabbet to rabbet dimensions = 78 1/4...
Hinge backset is the dimension from the leading edge of the hinge to either the stop on the frame or to the stop face (push side) of the door. For operating clearance, the hinge backset on the d...