Will Sargent cylinders fit into AL series locks

RELATED FAQS

Question
Answer
Medeco does offer a key-in-lever cylinder to fit the Schlage ND.You will need to contact Medeco for the cylinderSpecify a key-in-lever cylinder to fit the Schlage ND lock.They will supply a cylinde...
The JD YA6 tailpiece is intentionally designed such that the tailpiece cannot be installed at the same time as the cylinder.  Interchangeable cylinders assume that the lever and taipiece is in...
See the JD Yale Lever installation instruction HERE
Standard Schlage cylinders will not fit in Yale locks, but Schlage does offer special retrofit cylinder that, when ordered, can fit into specific Yale locks.  See below for retrofit options.  ...
Indicator not extended Indicator extended
The indicator on a cylindrical hotel lock is a small pin that projects outward from the face of the cylinder plug (Figure 1) when the inside push button is depressed.  When this pin is pr...
The minimum stile for each lock will depend on the backset and the rose diameter/escutcheon width.  See the Schlage Minimum Stile Guidelines  for the minimum stile for each...
The S-Series and S200-Series outside keyed spindle was redesigned in September 2008.   For locks manufactured BEFORE September 2008    The S and S200 lever cylinders required cy...
The AL and ND locks are not available in any stainless steel finishes.  The only option is either the 626 satin chrome or 625 bright chrome.
The standard door range for an AL lock is 1 3/8" to 1 7/8".  Using the supplied instruction sheet, align the springcage post to desired door thickness by adjusting the outside castle nut. See inst...
Key in lever Falcon cylinders do not work in Schlage locks.  The cylinders may fit, but there are no specific tailpieces created to operate any Schlage lock. SFIC SFIC is universal so Falcon and...
   Hotel cylinder in L9000 As long as the correct cam is used (Schlage clover), a Falcon Hotel cylinder will properly function in an L9486 hotel lock.
Only the Schlage ND-Series can be prepped to accept non-Schlage cores. All designs are supplied with the appropriate tailpiece Non-Schlage cores are NOT included Lever designs available vary d...
The Falcon Monarch 510L and 510L-NL trim will accept either a 1 1/4" Mortise cylinder with a straight cam or a 1 3/8" Mortise cylinder with a straight cam using the blocking ring provided with the ...
The AL series lock fits up to 1 7/8” door thickness out of box.
Click here for a list of available Schlage cams comparable to the Sargent 13-0660.
The AL and A trim is not compatible with each other.
The Sargent cams listed below work for all applications except 16 inside and 50 outside.  The equivalent Sargent cam is the 13-0660. Use the B520-736 for modular cylinder lengths of 1 1/8",...
The Primus cylinders are not designed to fit into the F locks.  They are too long and the tailpiece is oriented differently.
The RU lock can accept a Schlage Full Size core, but the cylinder suffix must be specified as "J IC-SC" so the correct parts are supplied. The tailpiece will come with the lock. Example: RU581J IC-SC
Refer to table 1 for the list of Schlage AL-Series cylinders.     AL-Series Cylinder Reference Table    Function  Cylinder Mechanism   Complete Cylinder   Non-Hotel Functions  ...
The T lock can accept a Schlage Full Size core, but the cylinder suffix must be specified as "J IC-SC" so the correct parts are supplied (including the tailpiece) Example: T581J IC-SC
The new AL FSIC driver part number is A700-052.  This driver snaps onto the back of the core similar to the ND, as opposed to it being assembled into the lock chassis with a retaining ring.  Th...
The L Series lock can fit into a door prepped for the SCHLAGE K Series with some additional prep as described here.  
K and L trim and parts are not interchangeable. 
The AL lock can not be ordered to accept any competitor full size core.  The ND lock should be used in these applications.
Specify the J cylinder suffix followed by IC-CR6 or IC-CR7 (6 or 7 pin Corbin core) Example: T581J IC-CR6  This will accommodate an 8000 or 8000-7 Corbin Russwin Full Size core.
The easiest method to obtain an AL lock for a 2" door is to specify a 2" thick door when ordering.  
Part required by function:2 each A700-043 driver & A700-034** lever insert in addition to the chassis parts below:AL10S – 2 hubs A700-028AL25D – 2 hubs 1 A700-028 (inside), 1 A700-030 (outside)...
Schlage offers Falcon Retrofit cylinders to fit many of Falcon's locks.  Table 1 below contains part number for T series locks.  Table 1 - Falcon retrofit cylinders