WHICH AUTOOPERATOR SAFETY SENSORS CAN WE USE FOR DOUBLE EGRESS APPLICATION

RELATED FAQS

Question
Answer
With Motion Sensors: Single Door - 2810/9530/9540, use 8310-3881 Sensor Package. 8310-3881 Sensor Package includes: 2 ea. - 8310-854 motion sensors. 1 ea. - 8310-877 header mount safety s...
The overhead concealed operators (2850/2860) will not work on a Double Egress frame because the doors are not in the same plane. You will have to use the surface mount (9553 / 9563) on Double Egres...
The 8310-877 Bodyguard Safety Sensor attaches (plugs in) to the P1 connector on the Senior Swing controller. The 8310-846 (761462-00) wiring harness "included" with the 8310-877 safety sensor is us...
 Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted.  Consists of a modified, heavy-duty door closer for manual oper...
There is no mullion for double egress openings.  Mullions only applies to the doors that open in the same direction.
Astragals are required on: 3 hour fire rated pairs: Double doors - swinging in the same direction Double Egress - swinging in opposite directions Fire rated Dutch Doors Fire rated 1 3/4" t...
An Astragal is an applied molding attached most commonly to the meeting edge of doors to: Protection against weather conditions Minimize the passage of light between the doors Retard the passa...
Chexit devices are NOT electric latch retraction.  In order for Chexit device to operate with an auto operator you will need to add a rim electric strike on a single door or a pair o...