where are Steelcraft hardware locations?

RELATED FAQS

Question
Answer
Panic Hardware and Fire Exit Hardware are two different types of exit devices, and the proper selection is determined by code requirements. Panic Hardware is an exit device which is tested for u...
The most obvious difference (in the device) is the lack of mechanical dogging on a Fire Rated Device.  There are some internal parts that may be different and the method it is secured to the d...
Hinge Spacing: All 4 1/2" and 5" butt hinge spacing 1. Opening heights 3'0" through 4'11 15/16" (one pair butt hinges) from under head CL 9 3/4" (top of door 9 5/8") from bottom of frame ...
Hinge Backset: On the frame = 5/16" On the door = 1/4"
Lock Spacing: All standard bored locks ANSI 115.2 (161, 61L type), for mortise lock ANSI 115.1 (86 type) all locations must be altered 3/8" lower, and standard strike (ASA type). 1. Opening ...
Steelcraft locates all butt hinges from the top of the door to the centerline of each hinge as standard practice: Locating hinges to the center line of the hinge keeps all hinge locations the sa...
Yes, glass light can be used or prepped in conjunction with the Von Duprin 94/95 Series INPACT device however there are dimensional limitations between the glass light and the InPact door preparati...
Glass lights available: Standard Glass Lights - The N4, N5 & V lite can be used at standard locations with out any modification. Glass Light Options - Other glass lights are available but ...
Maximum Dutch Door sizes are: Non Labeled = 4'0" wide X 8'0" High Labeled = 4'0" wide X 7'2" High Special sized Dutch Doors are available: Special size top and/or bottom leaves are availabl...
CO-100 now allows the PIN code length to be changed manually.  Each CO100 has a label that indicates its firmware revision.  Firmware revision 2.5.0 or higher support these...
CO-100 PIN length can range from 3 digits to 6 digits with firmware version 2.5.0 and higher.
Procedure to change PIN length: 1. Press {programming code (default is 97531)} then {*}.2. Press {99} then {*}, to enter Special Function Length Menu.3. Press {4} then {*}, to enter Pin Length M...
CO-100 now has NEW lock status reporting capabilities. Battery status, firmware version, hardware version and PCB serial number. See instructions below for these status menus.
EPT installation guidelines are as follows: Recommended location is 6" below top hinge per template Steelcraft will locate the power transfer prep at the Von Duprin recommended template locati...
"5, 10 and equal" Hinge Spacing: The industry terminology which usually refers to the Custom (NAAMM/HMMA) Door hinge locations. This location dictates: Top Hinge - located 5" from the underside ...
The location to the top of hinge will vary depending on hinge size used. 6'8" Frame with 1 1/2 pair of hinges (top to top): For 4 1/2" hinges from the head to top of each hinge is 7 1/2", 37 7...