what tubing is used for pneumatic exit devices

RELATED FAQS

Question
Answer
The maximum 925 tubing run length from the Control Box to the Door Closer is:  7980 Series Control Boxes --- 50 "Linear" feet from Control Box to Door Closer.  7900/7940 Series Control Boxes --...
PN33/35/98/99 Pneumatic exit devices are not usually used with RX or LX switches since the Pneumatic PN device is used instead EL to eliminate the electric from the device.
If using the LCN pneumatic control box as the air source for the Von Duprin Pneumatic devises then you have to use the LCN 925 tubing because of the size of air line fitting on the LCN co...
The Von Duprin Pneumatic PN98/99 series exit devices feature provides remote latch bolt retraction in hazardous areas where electrically operated devices would not be permitted.
The Von Duprin Pneumatic or "PN" device was designed for Intrinsically Safe Class 1, Division 1 applications.
 Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted.  Consists of a modified, heavy-duty door closer for manual oper...
The pneumatic operators are designed to function with an input air pressure to the 7901/7902 Series control box of 80 (min) 100 (max) PSI, and an output pressure of 60 to 80 PSI to the pneumatic (2...
4810 series is a Top Jamb Pull Side application. 4820 series is a Top Jamb Push Side application. 4840 series is a Parallel Arm Push Side application.
The 4840 and the 4810 are they only cylinders that can be interchanged, they use the same cylinder for their individual applications.
You will need to check with the other manufacturer.  Check the template for the other manufacturer to see if the hole pattern for the trim and the cylinder location would match up.  The VR trim cou...
 The Falcon Monarch 718C and the 718NL trims can be used on the 25-C exit device.  The 718C trim is listed in the Price Book for the 25 series  The instructions attache...
Equivalent to the Schlage D series line with a C keyway. Part number 21-002.
Von Duprin does not recommend using XP98/99 devices with any electric strike.   Von Duprin recommends using the standard 98/99 rim device.  The XP device has 2000 pound holding forc...
This is not a recommended application as the electric strike does not have the same holding force as the XP98/99 rim exit device. The electric strike has 1500 pounds of holding force whereas the XP...
The 909 strike is used in single and paired non-fire rated and single fire rated openings.  The 954 strike is used in fire rated paired openings.
The 1609 strike cannot be used with Von Duprin XP98/99 exit device.
You should use the LX switch with the Von Duprin surface vertical rod exit device because the rods are exposed and are vulnerable to attack. IE, the top rod can be grasped and forced down to retrac...
The 5100 electric strikes are for use with cylindrical locks only.  Instead use the following:6211 electric strike is used with mortise lock without deadbolt on a new single door, hollow ...
The 22, 33/35A and 98/99 rim exit devices: The 6111 is the most common electric strike to be used with these devices 6112 and 6113 electric strikes also could be used The 6300 surface mount el...
Recommendation is to use mild soap with a damp cloth to clean an exit device.
Panic devices are not designed for exterior application. As with any mechanical device, exposure to the elements may affect the operation and life of the device and/or finish and may void&n...
Water and electricity do not mix.  Von Duprin electrified devices can NOT be used in an exterior environment.
There is not a fully self-contained delayed egress like a Von Duprin Chex-It device but the Falcon RX-25 Series can perform a delayed egress by using the DE5300 controller, power supply, ...
Von Duprin Exit Devices (33A/35A, 98/99, etc) are handled on a case by case basis regarding their ability to handle salt and chemical environments. Our powder coated finishes US28 (Anodized Alum...
Current EL and QEL baseplate conversion kits can be used on all latching types of the 33/35 series (non "A" version which were manufactured prior to 2003).  At one time, the obsolete black EL ...