what products are Windstorm tested

RELATED FAQS

Question
Answer
The following Securitech products have been tested and approved for use on Steelcraft Paladin doors: 5300 series devices- 3 point surface and concealed devices 7300 series devices- 3 point surf...
SDI 114 is no longer published as an SDI performance standard. The new SDI standard for acoustical Performance is SDI 128-09 Steelcraft does offer products that have been tested in accordance wit...
HH hurricane rated devices usually have a deferent strike and fire rated mullion. Standard 98/99 series exit devices can be converted to HH by changing the strike and mullion on pair of doors. ...
No, the 33A is not compatible with the AD and  CO 993  chassis units. The  33A can only be driven in a clockwise direction. This would restrict it to right hand installs only.
Schlage does not test their locks for ballistics or bullet resistance.
STC stands for Sound Transmission Class. An STC (Sound Transmission Class) is a single number rating system derived from measured values of sound transmission loss in accordance with ASTM E90 and...
ASTM E-119 is a test standard for walls, partitions and floor or roof systems: This test standard is also used for ceramic type glasses when used as window wall and/or borrowed light frames. ...
Auxiliary fire latch is tested only from door to door latching by Von Duprin. Some door manufacturers have tested our devices LBR and use additional fire latches to pass the fire test. Contact the ...
Look to see if the  "Fail Safe?UNLOCK" on communication failure is set and you have lost communication.
The "Unlock on READ" from diagnostics will clear with the next AD400 heartbeat, automatically. It will also clear with successful communication to a working access control panel. 
 If the AD-400/AD-401 is LINKED to a PIM400-TD2 and all credentials including invalid cards are granted access, the PIM400-TD2 is not communicating with the Access Control Panel, and the lock is st...
Or force a strike input to the PIM400-TD2. Short J8-1 and J8-2 (Door 1), Short J7-1 and J7-2 (Door 2) on the PIM400-TD2
MultiPoint locks are three-point locking systems that secure the door at three points – top, bottom, and traditional center latch location. Operating just like traditional locks, MultiPoint locks a...
The EL option is not available with WS98/99 series exit devices.  
The U-Factor, R-Value and K-Thermal Rating are measurements of thermal transmission through building products. U-Factor: Overall co-efficient of heat transmission passage through a built-up panel...
Steelcraft offers all the standard lights as well as special size glass lights in the H-series door. Effective April 1, 2012, (Bulletin # B-100.12) the default for Dezigner Trim in H-Series Doors...