Can the electric strike be used with a vertical rod device on a fire-rated door?
Resolution:
Not for use in fire rated openings.:
Can the 9927 exit device be installed Less Top Rod?
Resolution:
The top rod is required for proper operation. The top latch controls both the top & bottom rods and without the top latch/rod the bottom latch would release when pushpad or trim was used but then ...:
What would cause a 4600 operator to click a few times when the actuator is pushed, but not open the door?
Resolution:
If a 4600 clicks, but won't open the door: Verify proper connection of all the control box connectors. Verify correct manual operation of door. Verify actuator connections and any strike/maglo...:
What is the part number for the Fail Safe slider for the 6211?
Resolution:
The sliders are different between the 6211 and 6211WF. The FS slider part number for the 6211 is 090591 The 6211WF FS slider is 090798. :
What is the difference between LR and PL latches on Von Duprin 8827 exit devices?
Resolution:
ES (electric strike) latch is only used with the 8827 less bottom rod on a non fire rated exit device with a 6111 electric strike.:
Will the 9100 series Benchmark III power an electric strike?
Resolution:
The Benchmark III control has a 24VDC, 2.5 amp power supply, and built in relay for controlling electric strikes or other accessories less than 2.5 amps current load. For a fail secure strike, r...:
What is the part number for a FSIC?
Resolution:
DESCRIPTION PART NUMBER Conventional Core 23-030 Conventional Core less logo 23-031 Primus Core 20-740 Primus XP Core 20-740-XP Primus Core less logo 20-741 ...: