The holding force on an SE/ME Series door closer is approximately 35 lbs. and they can be manually pulled out of hold open with approximately 35 lbs of force.
Currently, the 914KIL trim will only work on 1 3/4" doors.
The SEH is an "electronic holder" (ONLY) that is used to hold open a Fire Rated opening. It requires a door closer to be mounted on the opposite side. It is normally used on an existing opening wit...
The 4040SE uses the regular arm for any Push Side mounting (minimum 28" door width). ST-2788 (a special arm and track) can be used to mount a 4040SE on the Push Side of a smaller (narrow) door. Sm...
Yes, the holes on the door would be covered up by the 25-R-L device.
The (4) center case mounting holes are in the same location but there are some small modifications that will be needed like the 3/4" dia. hole at device CL for the main cam clearance shown o...
The AD or CO - 993 is NOT compatible with a Von Duprin 98/99 Concealed Vertical Rod exit device on wood doors.
For a door closer that tries to open the door instead of closing it:The closer body could be mounted backwards on the door - check instructions for proper closer orientation.It could be the wrong h...
All Von Duprin 98 and 99 trims include screws for both 1 3/4" and 2 1/4" thick doors.
Von Duprin 98/99 and 98/99XP Rim/SVR/CVR(steel door only)/Mortise exit devices are compatible with AD200, AD250, AD300, AD400, AD401-993 exit trims.
Von Duprin 22/22F Rim/SVR exit devices are compatible with AD200 and AD250-993 exit trims.
Falcon 25 Rim exit device is compatible with AD200 and AD250-993 exit trims.
The 4040SE is non handed and can be mounted on the push or pull side of the door.
The Schlage L0170 is not available with the L escutcheon design because due to the narrow size you cannot fit the mounting plate underneath.  The mounting plate must sit on a "diamon...
The AD200, 250, 300, and 400 trims will work with the Von Duprin 98/9975 mortise Exit Devices.
Reveal is the distance or measurement from the face of the door out to the face of the frame on the push side of the door.Other related terms:Door face - The exposed surface of door visible wh...
It is always recommended to point installers to the industry installation manuals which are very comprehensive and are ANSI documents. SDI (Steel Door Institute) installation manual can be found...
A 1460 Pull Side can be mounted standard template for 180°, frame and trim permitting.
A 4030 Pull Side can be mounted standard template for 180°, frame and trim permitting. 
A 1260 Pull Side can be mounted standard template for 180°, frame and trim permitting.
The L Series lock can fit into a door prepped for the SCHLAGE K Series with some additional prep as described here.  
K and L trim and parts are not interchangeable. 
The 1260, 1460, and 4030 regular arm closers on the pullside will allow 180° door opening and can be held open at 180°, frame and trim permitting.
When CX99L-BE is not armed with key cylinder on the device or shunted by card reader, the exterior 996LBE lever trim will release.
The Date Code and Closer Size are stamped in the backside of the closer body. Closer Size: If the number is "1", the closer is a 2031 or 5031. If the number is "3", the closer is a 2...
Yes, glass light can be used or prepped in conjunction with the Von Duprin 94/95 Series INPACT device however there are dimensional limitations between the glass light and the InPact door preparati...
Glass lights available: Standard Glass Lights - The N4, N5 & V lite can be used at standard locations with out any modification. Glass Light Options - Other glass lights are available but ...
The maximum opening is 120° with the 4041/4041XP standard templating on the pull side of the door.
The 4170 cover plate can be used to cover the 86 & 161 prepped doors.
The 4000T Series closers have a maximum opening of 90°.
No, the 98/99 series mortise exit device should be ordered as NL less trim. IE, 9875NL-L/TRIM. NL-OP suffix is normally used with the 98/99 series rim, surface and concealed vertical rod devices wh...
Von Duprin does not offer any lever trim or pulls that through bolt to the Guard X device.  Ives has the 8102-6 and 8105-6 pulls that can be lined up with the mounting screws of the exit device b...
Locate closer and arm from the centerline of the swing clear hinge pin.
If the 912L was shipped after February 28,  2011, Check the installation instructions, step 3 to be sure all parts are installed on the trim correctly, even if the trim was received in th...
The 4330 / 4430 is an obsolete ME closer replaced by the 4310ME or 4410ME Series.
The 4011 can only mount on the Pull Side of the door and the 4111 can only mount on the Push Side of the door. Differences - The 4011 and the 4111 cylinders are different and the pinion shafts are...
The following steps are required to convert the Von Duprin 98/9975L from classroom to night latch function: Order new 996L-NL-M trim and reset NL drive screw in mortise lockbody as set from...
If a door is being held open by the LCN SEM 7800/1900 magnet or any ME/SE Series Sentronic LCN closer, you can remotely release that door to close by ordering the following parts and wiring per ST ...
The Falcon SC71 is an exact replacement for the Norton 7500. The LCN 1460 or 4040 Series closers could be used, the mounting hole pattern is different.
Hold Open Closers & Magnets (Fire/Life safety products) provide a wide range of solutions.  Single or multi-point hold open closers Utilize an electromechanical closer. Hold the door o...
The 4040(XP) door closer can be used as a temporary replacement in a 4630/4640 operator to provide manual control of the door while the 4630/4640 closer cylinder is being repaired or a replacement ...
Because of the new extended LCN warranties and the desire to be consistent across the entire Allegion premium brands, LCN will be moving away from offering an out-of-warranty repair service beginni...
A 1 1/4" mortise cylinder with straight cam (similar to the Schlage B502-191) or a 1 1/2" mortise cylinder with straight cam using supplied spacer collar. Cylinder length does not chan...
LCN does not supply Allen wrenches, the size that LCN uses, are standard sizes that every installer will have in their tool kit. 3/32" Allen wrench for adjusting regulation valves: main speed, lat...
When dealing with glass lights in doors, there are three (3) critical dimensions which must be coordinated: Exposed Glass Size (EGS) - the horizontal and/or vertical dimensional size of the vision...