what does hold open stop mean?

RELATED FAQS

Question
Answer
The correct method (process) for setting the hold open is: The 4110 HEDA arms are handed, verify correct hand arm. (RH or LH stamped on shoe bracket) Loosen the hold open nut at shoe bracket. ...
If an ME Series closer creeps shut or will not hold open, Verify proper voltage is being supplied to the closer, if correct Check the on/off switch. Verify the voltage on the 2 pin co...
The ES Filter started to ship with these units (Senior Swing/Benchmark/Falcon) on 4/22/2013.  The ES Filter kit will help eliminate line noise from an Electric Strike if used. 
On the Senior Swing, if you have line noise from a strike the unit will go into an Error Code on the Control Box (Er14) and will not operate.  Adding the ES Filter, which is a diode, will eliminate...
On the Benchmark and Falcon, if there is line noise from a strike then the unit will lose it's hold open time.  Adding the ES Filter, which is a diode, will resolve this issue and the unit will hol...
 The correct method (process) for setting the hold open is: The 4010 hold open arms are handed, verify correct hand arm. (R or L stamped on main arm) Loosen the hold open nut. Opened the door ...
If mechanism cover plate causes the EL solenoid to drop when slid over the solenoid, the solenoid plunger requires adjustment.  You must lengthen the rod by turning the hex nut in front of the plun...