A 3' exit device can not be modified to a 4' exit device. You will need to replace the device with a 4' one.
Panic devices are not design for exterior application. As with any mechanical device, exposure to the elements may affect the operation and life of the device and/or finish and may void&nbs...
Water and electricity do not mix.  Von Duprin electrified devices can NOT be used in an exterior environment.
The Von Duprin Pneumatic PN98/99 series exit devices feature provides remote latch bolt retraction in hazardous areas where electrically operated devices would not be permitted.
The Von Duprin Pneumatic or "PN" device was designed for Intrinsically Safe Class 1, Division 1 applications.
 A 1 1/4" cylinder with straight cam is required for the Von Duprin SD (Special Dogging) exit device option.
The cylinder cam must be inverted with the SD option to work properly.
The hole should be drilled in the field once the end cap is located on the door.  It is a 5/8" hole, that is located 5/16" from the end of the mechanism case. See installation instruction of t...
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F, 8875-F or...
Von Duprin warrants that the product manufactured by it and delivered here under will be free of defects in material and workmanship for a period as follows: Exit devices and trim for 36 months...
The 376T trim activates and connects to the 33/3547A top rod. The 360T activate and mounts to the 33/3547A center case.