von duprin mortise

RELATED FAQS

Question
Answer
The AD200, 250, 300, and 400 trims will work with the Von Duprin 98/9975 mortise Exit Devices.
The Von Duprin 7500 mortise lock body will replace the old style 34 and 58 lock bodies. Order a 7500 mortise lock in the proper finish. The old style strike must be replaced with 575 strike becau...
Von Duprin KR (key removable) mullions requires a 1-1/8" or 1-1/4" mortise cylinder with the standard straight cam, the cam is not inverted. Please see chart below for part numbers. 
instructions
The Von Duprin CD kit comes with the cover plate machined to accept the cylinder dogging mortise cylinder.1 1/4" mortise cylinder with an inverted straight cam is required for CD option on Von Dupr...
20-059 is the standard straight cam FSIC housing only used with Von Duprin, Monarch, and other straight cam applications. 30-032 is the straight cam FSIC housing only for the outside of the Schl...
The Von Duprin 7500 mortise lock body ships in the NL mode.  Either the function of 7500 lock body has not been changed to the Classroom function or the NL Drive screw is not all the way down. Step...
  Tips for changing the function: The NL Drive screw will not be visible when lock body is set to Classroom function There is locktite on the screw that makes it seem like its turned down enou...
The Von Duprin 370 series control required a 1 1/4" mortise cylinder and will not operate with 1 1/8" mortise cylinder.
The center line of the L9000 mortise lock is 7/8" above the center line of the 6211 electric strike. This is the "C" dimension given on the second page of the 6211 template.
To convert the Von Duprin 9975NL(Night Latch or Storeroom) to 9975L (Classroom) exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL ...
To convert the Von Duprin 9975L to 9975NL exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL screw on 7500 mortise lock counter clo...
No, the 98/99 series mortise exit device should be ordered as NL less trim. IE, 9875NL-L/TRIM. NL-OP suffix is normally used with the 98/99 series rim, surface and concealed vertical rod devices wh...