Von Duprin field paint procedures

RELATED FAQS

Question
Answer
Steelcraft frames and doors are furnished with a high grade, low gloss, baked-on prime paint that provides the best possible protection against corrosion, abrasion and weather, and is an excellent ...
Steelcraft does not offer factory powder coated doors and/or frames. Powder coatings usually require heat between 300 to 400 degrees to melt and cure the powder coat. The higher heat can ca...
The following steps are required to convert the Von Duprin 98/9975L from classroom to night latch function: Order new 996L-NL-M trim and reset NL drive screw in mortise lockbody as set from...
GrainTech® doors are not available with different finishes on the inside and/or the outside door panels. Both panels must match. Standard GrainTech® finishes include: Birch Ash Oak Maple Ma...
All Steelcraft Frame, Door and Architectural Stick components will receive one coat of sprayed-on factory paint which is a baked-on, rust-inhibited primer that conforms to the industry standard ANS...
The 510L can be converted to a nightlatch 510L-NL by changing out a few parts to the trim. See 510L to 510L-NL conversion instructions for required parts that will need to be added/r...
Steelcraft offers two optional types of reinforcements for open section header to be installed in distributor shop or in the field: Full profile sleeve; is a 14 gauge, 16" long part to fit the p...
-On the AD series offline locks only you can change the lock function from Classroom/Storeroom to a Privacy, office or apartment function out in the field. - This is done via the HHD/SUS using...
The release delay time for the Chexit is programmed into the Chexit module and cannot be changed in the field. The Chexit module would need to be replaced to reduce the release time of the Che...
Primer
Followings are the list of the electric latch retraction EL/HDEL (hex dogging), QEL (quiet) kits: 114317-00 QELA Mod. Conv. Kit 040061-00 QELA Mod. Conv. Kit...
The Von Duprin 9947 metal door device can be converted to the 9947WDC wood door device by purchasing conversion kit number 050134-XX. This conversion kit is only for the panic version only. Fire ...
Recommend to order a new 990NL-R/V or M trim to change from TP/Classroom function to NL/Storeroom function. You will also need to reinstall the NL drive screw back into into the mast...
A 3' exit device can not be modified to a 4' exit device. You will need to replace the device with a 4' one.
The DS is Dual Monitor Switch for Von Duprin 6000 series electric strikes. DS option cannot be added to a Von Duprin 6000 series electric strikes in the field. It is only available factory inst...
The Von Duprin 230L trim can be re-handed in the field by following the steps listed in the 230L/L-BE Instructions
The Von Duprin E996L electric trim is field reversible. See attached 996L installation instructions on page 2 for rehanding procedure.  996L Installation Instructions
The Von Duprin 6000 series electric strike can be converted by ordering the appropriate kits below.  Kits include the solenoid, plunger, spring, and washer. 6000 Series solenoid Kit 12VDC -...
The attached table shows the part numbers for LX-RX and LX-RX-LC switches field installed.