VON DUPRIN EXIT DEVICE TEMPLATES

RELATED FAQS

Question
Answer
The conversion kit does not contain a new mechanism case cover plate.  If a cover plate is desired you would need the Fire or Less Dogging Cover Plate for EL conversion kit and panic cover plate fo...
Cylinder dogging (CD) and an RX switch can be ordered together with 33/35 or 98/99 series.
This can be done ONLY with non fire rated exit devices.
Von Duprin Exit Devices (33A/35A, 98/99, etc) are handled on a case by case basis regarding their ability to handle salt and chemical environments. Our powder coated finishes US28 (Anodized Alum...
The Von Duprin 994L series trims were square on top and bottom.  They were discontinued in July 2010.
Von Duprin warrants that the product manufactured by it and delivered here under will be free of defects in material and workmanship for a period as follows: Exit devices and trim for 36 months...
The following items may cause the exit devices top latch from being held in the retracted position. 1. The top or bottom rods are out of adjustment. 2. The top latch hold back...
Following exit devices 2227/F, 33/3527A/F, 33/3547A/48A/F, 98/9927/F and 98/9947/48/F have similar rod adjustment procedures. All top latches control the bottom latch assemblies. When do...
The Von Duprin 98/99EO exit devices will accept any of the exterior trims that we offer for 98/99 exit devices without any extra parts. 996L, 996L-NL, 996L-DT, 996L-BE, 990NL, 990DT, and 110NL a...
There is not a chart that shows which sex bolts are required for Von Duprin or Falcon/Monarch exit devices.
To order Von Duprin exit device reference the "Additional information/How to order" section in the Von Duprin catalogs. All Von Duprin device series Catalogs are available on website.
Frascio is a company that provides decorative lever sets for many of Allegion products.  More information can be found on their web site at WWW.frasciointernational.com.
If the spring on the Von Duprin exit alarm ALK board is not located correctly as shown on the instructions, then the vibration from the horn allows the cylinder to turn and shut the exit alarm ALK ...
You cannot lock the push side of the exit device as a panic device by design must allow exit.  Any attempt to block an exit is forbidden by code.
 Click Here to view the Hollow Metal or Wood Door Templates for Von Duprin devices   The E996L trim and RX98/99 devices  use the standard 996L and 98/99 templa...
Please contact the Allegion Product Support Team on all questions or inquiries pertaining to hardware finishes warranties. Please send an e-mail to the applicable Product Support team:Closers_TechP...
266M is on all Von Duprin exit devices and does not identify the device.
The 376T trim activates and connects to the 33/3547A top rod. The 360T activate and mounts to the 33/3547A center case.
The only electric trim that is used with the 98/99 series exit device that Von Duprin offers is E996L lever trim.
E996L electric trim is used to lock or unlock the lever trim for the 98/99 series exit devices.
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F, 8875-F or...
The 909 strike is used in single and paired non-fire rated and single fire rated openings.  The 954 strike is used in fire rated paired openings.
The 1609 strike cannot be used with Von Duprin XP98/99 exit device.
Please see the Maintenance Kit Manual for information on device lubrication as well as complete breakdowns and parts lists for Von Duprin exit devices.Exit devices and latc...
The Von Duprin 372L & 370L/BE series trims are discontinued and there are no replacement for them.  The new 33A/35A series exit devices use 360L trim. 370/BE trims were used with old style 33/35...
Yes, the current conversion kits will fit the old style/obsoleted 35 or 35 series vertical rod exit devices. 
A standard exit device can't be modified to a fire rated exit device.  A new device must be purchased.
The Von Duprin Guard-X exit device is not fire rated because the deadbolt is not spring loaded. Therefore, there would be no positive latching as required on a fire rated opening. 
Hardware falling off a door is caused by one or all of the following issues: Field abuse Improper internal reinforcements in the door Improper field preparation The top or bottom rod case can...
Panic Hardware and Fire Exit Hardware are two different types of exit devices, and the proper selection is determined by code requirements. Panic Hardware is an exit device which is tested for u...
The most obvious difference (in the device) is the lack of mechanical dogging on a Fire Rated Device.  There are some internal parts that may be different and the method it is secured to the d...
The 98/99 rim and vertical rod exit devices are shipped with NL drive screw to function as a Night Latch. To convert the device to Class Room, remove the NL Drive Screw on 98/99 center case ass...
Attach is the instruction and template for 237L device, 237 Instructions.
We have several blank trims listed in the price book to cover existing trim prep in door.  DEVICE EO TRIM   22  230EO  88  880EO   98/99  990EO or 996EO*  33A/35A Rim, 33/3...
Equivalent to the Schlage D series line with a C keyway. Part number 21-002.
Von Duprin does not offer any of the danmark lever designs by Schlage.