HD-EL conversion kit for 3 feet exit device is 050384-00 and for 4 feet is 050385-00.
To convert the Von Duprin 360L/TL from nightlatch to classroom or from classroom to nightlatch invert mortise cylinder cam.
Current EL and QEL baseplate conversion kits can be used on all latching types of the 33/35 series (non "A" version which were manufactured prior to 2003).  At one time, the obsolete black EL ...
The E996L is only shipped FS fail safe from the factory but can be converted to FSE fail secure.  To convert the 996L to E996L (fail safe or fail secure) follow step 1 of the attached installa...
The strike will always be DC.  By using a SO24 or SO12(rectifiers) you will be able to convert the AC waveform from a transformer to a DC waveform that will be acceptable by the 6000 series strikes.
You must have the Von Duprin NL Cylinder plate part number 967484-89 to convert the 370 series controls from classroom function to night latch function. If new installation, use the NL cylinde...
No, the back plate for 880K-knob trim is the same as for 373L-lever trim. Since 373L is a narrow style trim it require to use the 889 cover plate with this trim.
The conversion kit does not contain a new mechanism case cover plate.  If a cover plate is desired you would need the Fire or Less Dogging Cover Plate for EL conversion kit and panic cover plate fo...
To convert the Von Duprin 98/99 Rim or Vertical (Rod or Cable) Exit Device with functional lever (996L-R/V) to act like a rigid lever (996L-NL-R/V) with key over ride follow these steps: Remove ...
Followings are the list of the electric latch retraction EL/HDEL (hex dogging), QEL (quiet) kits: 114317-00 QELA Mod. Conv. Kit 040061-00 QELA Mod. Conv. Kit...
The Von Duprin 7500 mortise lock body ships in the NL mode.  Either the function of 7500 lock body has not been changed to the Classroom function or the NL Drive screw is not all the way down. Step...
  Tips for changing the function: The NL Drive screw will not be visible when lock body is set to Classroom function There is locktite on the screw that makes it seem like its turned down enou...
There is no conversion kit for Von Duprin Chexit device.  If delayed egress Chexit device is required, the entire device must be replaced.
The Von Duprin EL option can be added to any existing 33A/35A, 98/99 series exit devices. 
Followings are the steps to convert the Von Duprin 88TP to 88L device. Need to replace the back plate on the 88 exit device, part number 050103. Order a 373L trim and specify handing. Recomme...