von duprin conversion kit

RELATED FAQS

Question
Answer
The 050672 is the part number for rim or vertical rod device and 050673 for the mortise device.
The Von Duprin EL33A/35A/98/99 devices can be converted to the QEL devices by getting correct sized QEL conversion kit and a 900-2Q option board for the PS914 power supply. 3' Conversion Kit #05...
Recommend to order a new 990NL-R/V or M trim to change from TP/Classroom function to NL/Storeroom function. You will also need to reinstall the NL drive screw back into into the mast...
The part number for hex dogging conversion kit for 99 devices is 050114.
Offset link for 98/9947WDC is not available by itself. You need to purchase the 98/9947WDC conversion kit, 050134.
You can only use one GBK Glass Bead Kit (1/4") per device on fire rated openings. Glass Bead Kit is for use on doors with raised glass beads.
To convert the Von Duprin 360L/TL from nightlatch to classroom or from classroom to nightlatch invert mortise cylinder cam.
There is no EL conversion kit for a 2390, the device will need to be replaced.
Attached tables provide the back plate conversion kit for all 88 series Exit devices. 88 Back plate conversion Chart
The 900-2Q board is no longer available. For warranty purposes, QEL conversion kit and 900-2RS board are required. The 900-2RS replaces the 900-2Q board.
The circuit board is sometimes referred to as a "module" in the field.
To convert the Von Duprin 9975NL(Night Latch or Storeroom) to 9975L (Classroom) exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL ...
To convert the Von Duprin 9975L to 9975NL exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL screw on 7500 mortise lock counter clo...
The part will be configured as CONVERT.XXXX part numbers. The customer need to specify the following criteria. Required:   Series 94 or 95, Fire or Panic , 3 feet/4feet or 2 feet 6 inches/2 feet...
Conversion kits are available to convert many popular functions.Conversion kits manufactured on or after January 30, 2017 will have the new enhanced ND spring cage, lever, plunger and buttonCo...
For all available ND Series Conversion Kit part numbers, click here.
The Von Duprin 4754, 4854, 9954, and 9854 mullions can be converted or ordered with key removable option. KR54-F kit is the conversion kit to convert the above mullions to key removable mullion.
The current draw of a Von Duprin exit alarm ALK is .25 amp when alarm is activated.
To convert the Von Duprin 6000 series electric strikes from FS to FSE  or from FSE to FS follow these steps: Remove the electric strike face plate. Remove the strike box cover pl...
Part numbers: FS slider, part # 970387 (6211WF/6212WF/6221/6223 only) FS slider, part # 970388 (Except 6211WF/6212WF/6221/6223) FSE slider, part # 970388 (6211WF/6212WF/6221/6223 only) FSE sl...
The RX switch can be installed at the factory when device is ordered or in the field with part# 650359-00. Installation instructions here will show how the RX swi...
Cylinder dogging CD is not available with 22 series exit device.
The conversion kit does not contain a new mechanism case cover plate.  If a cover plate is desired you would need the Fire or Less Dogging Cover Plate for EL conversion kit and panic cover plate fo...
Followings are the steps to convert the Von Duprin 88TP to 88L device. Need to replace the back plate on the 88 exit device, part number 050103. Order a 373L trim and specify handing. Recomme...
You need to purchase the 050388 (RHR) or 050389 (LHR) and specify the finish.
This is available.  You will need the SD center case kit, SD center case cover, and EL conversion kit.
The Von Duprin CD kit comes with the cover plate machined to accept the cylinder dogging mortise cylinder.1 1/4" mortise cylinder with an inverted straight cam is required for CD option on Von Dupr...
Followings are the list of the electric latch retraction EL/HDEL (hex dogging), QEL (quiet) kits: 114317-00 QELA Mod. Conv. Kit 040061-00 QELA Mod. Conv. Kit...
The Von Duprin 6000 series electric strike can be converted by ordering the appropriate kits below.  Kits include the solenoid, plunger, spring, and washer. 6000 Series solenoid Kit 12VDC -...
Von Duprin offers two options:The CDSI/HDSI Dogging Indicator provides an at-a-glance verification of the status of the door from inside of the room. Visible “LOCKED” and “UNLOCKED” indicators show...
We offer a couple different HD-QEL options:Hex key dogging (HD) is now available with Von Duprin non fire rated QEL33A/35A/98/99 electric exit devices that were shipped after De...
ALK kit comes with standard RX switch. It can be ordered without the RX switch or with LX switch as an option.
There is no conversion kit for Von Duprin Chexit device.  If delay egress Chexit device is required, the entire device must be replaced.
No, the back plate for 880K-knob trim is the same as for 373L-lever trim. Since 373L is a narrow style trim it require to use the 889 cover plate with this trim.
You need to order the EL98/9947 or 3'  EL conversion kit.  This will fit on 28 1/8" minimum door opening on two vertical x vertical rod device doors.
Yes, part numbers for Falcon electric latch retraction EL conversion kits are as follows: 650147 for a 3' device. 650148 for a 4' device. 
To convert the 88TP to 88NL, device needs a correct back plate conversion kit, part number 050101 and a new 880NL trim.
Von Duprin has a maintenance kit part number 050046-00 and maintenance instruction, part number 941079-00 for 98/99 series devices. There are some common parts between 98/99 series and 22...
HD-EL conversion kit for 3 feet exit device is 050384-00 and for 4 feet is 050385-00.
The E996L is only shipped FS fail safe from the factory but can be converted to FSE fail secure.  To convert the 996L to E996L (fail safe or fail secure) follow step 1 of the attached installa...
There is no conversion kit to add EL or ED to an existing 1690 or 1790 series device. All of the components are built into the device, since the device does not have a separate baseplate.  You ...
There is not a conversion kit to electrify the LP373L lever control.  You need to order a complete E-LP373L-BE control through Engineering Specials.
The 98/99 rim device can be converted to double cylinder 98-2 or 99-2. Double cylinder features an inside key cylinder which locks or unlocks the outside trim (Classroom Function) and an outside c...
Followings are the reason for 98/99 exit alarm ALK not sound when push bar is activated. Make sure key switch on exit alarm ALK is turned on, wait for 20 seconds before you activating the pushba...
The Von Duprin EL option can be added to any existing 33A/35A, 98/99 series exit devices. 
To convert the Von Duprin 98/99 Rim or Vertical (Rod or Cable) Exit Device with functional lever (996L-R/V) to act like a rigid lever (996L-NL-R/V) with key over ride follow these steps: Remove ...
Kits are available per the following criteria.    Product Bulletin Required Series 94 or 95 Fire or Panic 3FT/4FT or 2 ft 6 in / 2 ft 10 in Finish  Optional LX...
A E996 conversion kit is required to convert the 996L/L-BE trim to E996L/L-BE electric trim. 050672-00 is the electric conversion kit for 996L rim or vertical rod exit device. 050673-00 is the ...
The 880 series trim will work with the 44 series device.
The Von Duprin LX kit would have a rod included in the kit.  The EL-LX switch kit does not include the rod as the EL dogging rod is used.
Yes, the current conversion kits will fit the old style/obsoleted 35 or 35 series vertical rod exit devices. 
You must have the Von Duprin NL Cylinder plate part number 967484-89 to convert the 370 series controls from classroom function to night latch function. If new installation, use the NL cylinde...
We ship the standard installation instructions because it contains enough information to show how to convert the trim from mechanical to electrical.
The Von Duprin 9947 metal door device can be converted to the 9947WDC wood door device by purchasing conversion kit number 050134-XX. This conversion kit is only for the panic version only. Fire ...
The attached table shows the part numbers for LX-RX and LX-RX-LC switches field installed.
You cannot convert the old Von Duprin 33/35 rim exit device to EL electric latch retraction as the device center case was different than EL33/35 rim center case assembly.