The sign for exit alarm, ALK, is SIGN-1.
Please see the Maintenance Kit Manual for information on device lubrication as well as complete breakdowns and parts lists for Von Duprin exit devices.Exit devices and latc...
Falcon (19. 24, 25, and XX) parts manuals for Exits are downloadable on the 
The current draw of a Von Duprin exit alarm ALK is .25 amp when alarm is activated.
AR1 is Auto-Reset 1.5 minute, AR3 is 3 minute, or AR6 is 6 minute option processed through engineering specials on a Von Duprin exit alarm ALK.
The part number for Von Duprin exit alarm ALK board is 101030-00.
The Chexit device has a different base plate and center case than the ALK.  The Chexit device would need to be replaced with an ALK device.
PCB only for the Alarm Kits prior to June 11th, 2012 is part #650335 and was used in the older 17 & 18 devices, 19, & pre June 2012 24/25's.
This circuit board will NOT work on the updated 24/25 Alarm Kits that released June 11th, 2012.