Side Light and Side Panel frames - Side Light and Side Panel frames are not KD (Knock Down), they must be assembled and welded.
All side lite and side panel frames must be assembled and welde...
NO - Louvers are not approved for installation in a fire rated transom / side panel frames.
NFPA Pamphlet 80 - paragraph # 6.3.4.4 states “Louvers shall not be installed in either transom or s...
Maximum hourly rating for a transom and side light or panel frame is 1 1/2 hour (90 minutes).
In masonry wall application the maximum is 13'6" x 12'2"
In stud wall application the maximum is 13...
Steel transom panels are available:
1 3/4" thick panels - supplied in L-Series (L20, L18 or L16-Series) laminated construction. Recommended down sizing is as follows:
Without Transom Bar
3...
Transom panels are available in the following constructions:
1 3/4" thick panels with interior construction similar to an L-Series door installed into a frame either
Without a transom bar - r...
When using 98/9927 with flush transom above:
You will need to use a 260U strike for flush transom applications OR a 260U-F strike for 98/9927-F fire rated device.
Transom Frame, Side Light Frame, Transom and Side Light Frame, Transom Panel Frame, Side Panel Frame, Transom and Side Panel Frame, Borrowed Light Frame