Question
Answer
A Double Egress frame is a double door frame prepared to receive two single-acting doors swinging in opposite directions (both doors are) the same hand. These openings are installed in cross corrid...
FE-Series, DE-Series; two way corridor openings
No. Fire rated double egress frames must be a stand alone 3 sided frame assembly. If transom lights and/or sidelights are required, they must be built and installed as separate Fire Window assemb...
Hospital Stops are available as either: 45° Hospital Stop - the stop of the frame terminates at a 45° angle 90° Hospital Stop - the stop of the frame terminates at a 90° angle The type of hos...
Hospital Stops are located at the bottom of the frame jambs and/or mullions. The integral door stops are terminates above floor line and is closed with a 45° or 90° angle to facilitate cleaning at ...
Yes, hospital stops are available on fire rated frames. Maximum approval = 3 hour Maximum sizes:  singles up to 4'0" x 8'0" pairs up to 8'0" x 8'0" Maximum hospital stop height 6" from bot...
Purpose: When there is concern for the weight of overhead wall construction, or, when multiple surface applied hardware components are being used. This continuous channel has the ability to spre...
DE-Series, DW-Series, FN-Series, F-Series, FE-Series, K-Series, MU-Series, FP-Series, FR (Double Egress Frame, Drywall Frame, Drywall Slip on Frame, Multi-Use Frame, Tornado Resistant)
Yes, wood doors can be used and installed in most hollow metal frame applications including FE-Series and DE-Series Double Egress frames. Caution - For fire rated applications the wood door manufa...
Fire Rated three (3) frames are available in the following maximum door opening sizes: F and FN-Series frame: 4' 0" X 10' 0" single door opening 8' 0" X 10' 0” double door opening MU-Ser...