Storeroom Nd series

RELATED FAQS

Question
Answer
A and AL product: Must use the 2 3/8" backset with the 41-005 extension linkD Knob and ND product: Must use the 2 3/4" backset with the 43-005 extension link
On ND locks manufactured on or after January 30, 2017 only the SFIC lever and SFIC driver are needed to convert the lock from Full Size conventional (PD) or Full Size IC (JD, RD, TD) prep to S...
On ND locks manufactured prior to January 30, 2017, the lever, spring cage and tailpiece needed to be replaced with the SFIC lever, SFIC spring cage and the SFIC driver . N123-056 - Outside sp...
Only the Schlage ND-Series can be prepped to accept non-Schlage cores. All designs are supplied with the appropriate tailpiece Non-Schlage cores are NOT included Lever designs available vary d...
Latches are sold separately, see current Pricebook for part numbers.
The ND40 does not have this option.  You will need to look at a mortise lock, L9496, or a deadbolt such as the B571.
Order the M204-198 thru-bolt jig, see Figure 1. Figure 1: M204-198 thru bolt jig The 40-080 was the old Schlage jig. The 030736-000-70 was the old Falcon jig.  When the jig changed to...
The 80 (Storeroom function) operates as follows: Key retracts latch (entrance by key only)
The 510L can be converted to a nightlatch 510L-NL by changing out a few parts to the trim. See 510L to 510L-NL conversion instructions for required parts that will need to be added/r...
You must have the Von Duprin NL Cylinder plate part number 967484-89 to convert the 370 series controls from classroom function to night latch function. If new installation, use the NL cylinde...
As of August 26, 2013, the ND75/95 in 626 finish comes standard (no additional charge) with indicator rose with black lettering and indicator arrow.For locks that shipped prior to August 26, 2013, ...
 Component  Function  Product  How to Order  Rhodes Indicator Rose  Classroom Security  ND75, ND95  XN12-035 (626 only)  Omega Indicat...
See attached bulletin.  Marketing bulletin with associated Von Duprin indicators listed.
If a blank rose is preferred over an indicator rose, the customer will need to order the lock less inside rose and order the inside rose (03-042) separately. Example: Lock Less each rose: Use ...
As standard the ND lock is not available in a 609 finish.
The ND12 and ND25 are both exit locks.ND12 Outside lever always fixed. Insidelever always unlocked for immediateegress.ND25Blank plate outside. Inside leveralways unlocked for immediate egress.
The letters GD, HD, BD, or BDC should be put after the lock function. EXAMPLE: ND53BD GD = Schlage SFIC core HD = Construction core BD = Less core BDC = Plastic temporary construction core
The storeroom lock function is described as follows: Latch bolt operated by key from outside or by operating inside lever. Outside lever is always inoperative. The following are storeroom functi...
MA581 is a Storeroom function mortise lock.
MA581 operation: Latchbolt operated by key from outside or by operating inside knob/lever. Outside knob/lever is always inoperative. Auxiliary latch deadlocks latchbolt when door is locked.
ANSI F84 Classroom Lock  Outside lever locked and unlocked by key. Inside lever always unlocked for immediate egress.   ANSI F86 Storeroom Lock  Outside lever fixed. Entra...
To convert a Schlage mortise L9080 function to a L9070 function purchase and replace the following:   L283-133, L9070 lock case  L283-040, spring cage (for outside lever)
Place any new orders per the following table ...
 Mortise Deadbolt Locks  Discontinued  Replace With  CO200MD  70-Classroom/Storeroom  40-Privacy  CO250MD  70-Classroom/Storeroom  40-Privacy  AD200MD  70-Classroom/Storeroo...
* NOTE: the AD300/400 devices simply communicate the change in Deadbolt Position status to the Host software.  The software then decides what action should or should not be taken at the device. 
To convert the Von Duprin 9975NL(Night Latch or Storeroom) to 9975L (Classroom) exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL ...
To convert the Von Duprin 9975L to 9975NL exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL screw on 7500 mortise lock counter clo...
Apartment Corridor Lock function is defined as a lock where the latch bolt operated by lever from either side, except when outside lever is made inoperative by a stop or mechanical means other than...
ND53PD (ANSI F109) Entrance Lock  Turn/push-button locking; pushing and turning button locks outside lever, requiring use of key until button is manually unlocked. Push-button locking; pushing bu...
The ND-Series RX,  the L-Series RX and latch monitoring switches are Form C - Single Pole Double Throw (also known as SPDT).
Only the Schlage D-knob and ND products are available with an extra long backset.  The part number for backsets over 5"-42" is XC03-069, this part will ship as an extension link to be used with a s...
Medeco does offer a key-in-lever cylinder to fit the Schlage ND.You will need to contact Medeco for the cylinderSpecify a key-in-lever cylinder to fit the Schlage ND lock.They will supply a cylinde...
As of February 2016, ND locks began shipping with a new latchbolt. The new latchbolt offers substantially improved performance in adverse door conditions (ex, with heavy door loading) andis more ro...
Prior to February 2016, using ND-Series locks on hollow metal doors required the use of latch spacers which prevent the latch from "fishtailing" (back end of latch moving from side to side). Latch ...
ND locks shipping on or after January 30, 2017 no longer require the use of the soft durometer spacer. Lever installation on the redesigned ND locks should not be difficult.
For ND locks shipping prior to January 30, 2017, the addition of the soft durometer spacer (SDS) on August 15, 2012 did affect the installation of the lever.  Ultimately, removing th...
There are two flat lip strike options: Specify XQ02-309 for a 10-013 strike - specify 7/8" Specify XQ07-351 for a 10-025 strike - specify 7/8"
ND-series locks manufactured on or after January 30, 2017 will ship with an improved spring cage and matching lever design. The design features are noted below. Because of this change, there a...
NOTE: ND locks manufactured on or after January 30, 2017 will no longer make use of the soft durometer spacer. The improved spring cage and matching lever eliminates the need for this spacer.Schlag...
03-042 is the part number for the inside or outside rose.
The anti-ligature trim is only available for the Schlage L-Series mortise lock and is not an option for the ND-Series.