stile dimension for full glass door type

RELATED FAQS

Question
Answer
Minimum dimensions to cutouts for glass lights: Vertical edge of door to edge of cutout = 5 29/32" Top of door to top of cutout = 6" Bottom of door to bottom of cutout = 10" Reinforcing chann...
The minimum stile and rail dimensions are to exposed glass are: Stiles = 6 13/16" Top Rails = 6 3/4" Center Rails = 7 1/2" Bottom Rail = 10 3/4" For high traffic and high abuse locations th...
The minimum stile and rail dimensions with glass trim are as follow: Top Rail: 6 1/4" top of door to exposed glass or 5 1/2" top of door to cutout Center Rail: 6 1/2" exposed gla...
When dealing with glass lights in doors, there are three (3) critical dimensions which must be coordinated: Exposed Glass Size (EGS) - the horizontal and/or vertical dimensional size of the vision...
A UL 20 minute fire rating is the maximum fire rating for a Full Glass (FG) door design. A14-Series door construction: Max fire rating is 20 minute. UL label only FG must use Over-Lapping Stee...
Steelcraft offers all the standard lights as well as special size glass lights in the H-series door. Effective April 1, 2012, (Bulletin # B-100.12) the default for Dezigner Trim in H-Series Doors...
The GCS (Glass Cutting Size) is determined by adding 1 1/4" to EGS (Exposed Glass Size) to both the height and width dimensions. Ex: EGS = 20" w. x 30" h. GCS = 21 1/4" wide x 31 1/4" high St...
Yes, glass light can be used or prepped in conjunction with the Von Duprin 94/95 Series INPACT device however there are dimensional limitations between the glass light and the InPact door preparati...
Glass lights available: Standard Glass Lights - The N4, N5 & V lite can be used at standard locations with out any modification. Glass Light Options - Other glass lights are available but ...
Glass lights are available in fire rated T-Series doors: Limited to one (1) light per door leaf with a maximum of 100 square inches of exposed glass. This applies to all hourly ratings a...
Maximum glass light size for a 90 minute (1 1/2 hour) door depends on the type of glass being installed. Wire glass = 100 square inches is max exposed glass when wire glass is used. Note - ma...
Maximum glass light sizes for 3 hour fire doors is as follows: Wire glass - not approved for use in 3 hour fire doors. Ceramic glass: UL & ITS/WH allow one (1) light with 100 square inc...
Maximum UL Fire Rated door sizes are as follows: A-Series: 4' 0" X 8' 0" single door 8' 0" X 8' 0” double door or pairs B-Series 4' 0" X 10' 0" single door 8' 0" X 10' 0” double doo...
ITS/WHI is "Warnoch Hersey". ITS/WHI is the formal designation for Intertek Testing Services / Warnock Hersey. ITS/WHI is an independent agency with testing, listing, in-plant inspection, and label...
Yes, Steelcraft doors and/or frames are available and can carry a UL, WH or FM label. The type of fire label (UL, WH or FM) is dictated by the specifications and local building code. Doors ...
Dutch doors are available as Fire Rated door assemblies and have similar component requirements as a single leaf fire door. Exceptions are as follows: The Dutch Door assembly must have a lock...
Glass Light is a preparation in a door for view window, vision and/or glazing including glass stop and glazing bead and may also be refereed to as a lite. Doors are available with a wide variety o...
Window kits are available for Steelcraft doors as either factory installed or prepared and installed by a distributor. Factory prepared light cutouts are supplied with Dezigner trim as st...
55 and 88 are both crossbar exit devices.  55 Series is used on narrow stile applications, 88 is for wider stile applications. See attached tables for 55 and 88 series minimum stile requirement...