The minimum stile and rail dimensions are to exposed glass are: Stiles = 6 13/16" Top Rails = 6 3/4" Center Rails = 7 1/2" Bottom Rail = 10 3/4" For high traffic and high abuse locations th...
Hospital Stops are located at the bottom of the frame jambs and/or mullions. The integral door stops are terminates above floor line and is closed with a 45° or 90° angle to facilitate cleaning at ...
For both DW and K-Series Drywall Slip-on frames, Steelcraft locates the compression anchor in the jamb soffits approximately 4" down from the head on each jamb. Regardless of door opening height: ...
A current PDF copy of the Steelcraft Tech Data Manual is available on the Steelcraft website and can be downloaded here. To order a printed copy of the Steelcraft Tech Data Manual contact the Cust...
Steelcraft does not offer doors with textured steel face sheets. Textured steel options (EP1 and EP3) were discontinued in 2000 due to lack of demand Steelcraft does offer optional GrainTech steel...
Hospital Stops are available as either: 45° Hospital Stop - the stop of the frame terminates at a 45° angle 90° Hospital Stop - the stop of the frame terminates at a 90° angle The type of hos...
The SL-Series door is a square edge non-handed door. A Hinge Filler  (also referred to as Hinge Spacer) is the small removable trim part located on the door between hinge leaf and hinge reinforcem...
GrainTech® doors are not available with different finishes on the inside and/or the outside door panels. Both panels must match. Standard GrainTech® finishes include: Birch Ash Oak Maple Ma...
Drywall Throat Fillers are used when wall thickness is between 1/8” (3mm) to 1/4” (6mm) less than the frame throat dimension, throat filler section(s) can be used to fill the gap, assuring the prop...
The 20 minute Fire Rating is a valid label and are commonly referred to as "Smoke and Draft control door assemblies". Depending on the local fire code and the openings's applica...