standard location for EPT
”
RELATED FAQS
Question
Answer
Where is factory recommendation for location of an EPT?
Resolution:
EPT installation guidelines are as follows: Recommended location is 6" below top hinge per template Steelcraft will locate the power transfer prep at the Von Duprin re...:
Where is the EPT location of a Pin-and-Barrel Continuous HInge?
Resolution:
The 600/700 Series EPT Template shows recommended locations based on the standard sizes, The customer can provide a different dimension measured from the top of the hinge to the Cen...:
What is Steelcraft's standard hinge locations for a 6'8" high frame from head to top of each hinge?
Resolution:
The location to the top of hinge will vary depending on hinge size used. 6'8" Frame with 1 1/2 pair of hinges (top to top): For 4 1/2" hinges from the head to top of each hinge is 7 1/2", 37 7...:
What is the part number for the 99 series NL drive screw?
Resolution:
The part number for 98/99 series NL Drive Screw is 970441-89. The NL Drive Screw is also available in package of ten, part number 090074-00 NL Drive Screw can't be substitute with a standard sc...:
Is the wiring harness found in both the KR 4854 and standard 4854 mullions?
Resolution:
The male and female receptacle wire assemblies (wiring hardness) are included in 48/9854 and KR48/9854 mullions. The wiring harness is the same in a 4854 and 9854 mullions. 105987 is the part n...:
Does a SEH require a door closer?
Resolution:
The SEH is an "electronic holder" (ONLY) that is used to hold open a Fire Rated opening. It requires a door closer to be mounted on the opposite side. It is normally used on an existing opening wit...: