standard ept location with continuous hinges
”
RELATED FAQS
Question
Answer
Where is the EPT location of a Pin-and-Barrel Continuous HInge?
Resolution:
The 600/700 Series EPT Template shows recommended locations based on the standard sizes, The customer can provide a different dimension measured from the top of the hinge to the Cen...:
Where is common cutout for Von Duprin EPT prep in Ives 224 Continuous Hinge?
Resolution:
Cutout depends on the size of 224 hinge. See 112HD/224HD-EPT template. 112HD/224HD continuous hinge Center line of EPT to top of the door 83 inches 30 inches 85 inches 32 inc...:
What is Steelcraft's standard hinge locations for a 6'8" high frame from head to top of each hinge?
Resolution:
The location to the top of hinge will vary depending on hinge size used. 6'8" Frame with 1 1/2 pair of hinges (top to top): For 4 1/2" hinges from the head to top of each hinge is 7 1/2", 37 7...:
What is the standard gap between a pair of doors hung with continuous hinges?
Resolution:
The standard gap between a pair of doors will be 3/16" when used with a Steelcraft "Z" astragal. If a wide inactive leaf is requested (no astragal) the gap between the doors will be...:
Where is the Fire Label located on a door and a frame?
Resolution:
Fire labels (UL, ITS/WHI or FM) are located as follows: Butt Hinges and Pivots: On the doors the fire label is located on the hinge edge between the top and 2nd hinge preparation. On the fram...:
What is the standard downsizing for a door leaf when using continuous hinges?
Resolution:
Doors require special downsizing for continuous hinges. The amount of downsizing depends on the hinge specified (manufacturer and type) and the hinge application (Full Mortise versus Full Surface v...:
Where is factory recommendation for location of an EPT?
Resolution:
EPT installation guidelines are as follows: Recommended location is 6" below top hinge per template Steelcraft will locate the power transfer prep at the Von Duprin re...: