Split key construction

RELATED FAQS

Question
Answer
Most key blanks have to be ordered in multiples of 50. Exceptions listed below: Classic and Primus Large Bows Classic and Primus Access Bows All Control Keys All Emergency Keys Primus Locko...
With split key construction keying there are two ways the construction insert is retained in the cylinder so that it won't fall out the back end of the plug, see Figure 1.  The&nb...
Split key systems are delivered in the highest level section on the key tip (insert): L - obverse or classic Y - reverse 0000 - Paracentric ZZZZ - Quad D000 - restricted Everest C000 - open...
A lock specified by a cylinder suffix BDC will be supplied with a disposable small format construction core, see Figure 1 below.  There is no metal key but instead the BDC cylinder has a ...
A small format disposable core is used as a SFIC construction core that is for low security applications and can be thrown in the waste bin after use.
The Schlage full size construction control key part number is 48-056-ICX.  The ICX suffix will change depending on if the key is for a new job or existing job.   New jobs: Specify "ICX"  E...