Question
Answer
Which exit devices work with the AD-Series exit trims?
Resolution:
Falcon 25 Rim exit device is compatible with AD200 and AD250-993 exit trims.:
What parts do I need to add to the bottom rod of my existing Von Duprin 8827 LBR exit device?
Resolution:
To add the bottom rod and latches on 8827LBR it requires Bottom Rod Kit part #050455-XX 8827 Rod Guide Kit part #50482-XX 8827 LR Bottom Latch Kit W/Cover part #050467-XX 304L Bottom Strike:
Can a pneumatic (PN) 33A/35A/98/99 exit device use the RX or LX switches?
Resolution:
PN33/35/98/99 Pneumatic exit devices are not usually used with RX or LX switches since the Pneumatic PN device is used instead EL to eliminate the electric from the device.:
Do Von Duprin Exit devices meet the 5 pound force requirement for opening an ADA handicapped door opening?
Resolution:
The 5 pound force requirement is in reference to the maximum force to swing the door, not the maximum force allowed to unlatch the exit device. Maximum allowed force to retract the Von D...:
Why is the electric E996L-FSE trim used with a Chexit CX99 exit device?
Resolution:
The E996L-FSE trim is needed if the application requires fail-secure operation from the trim side of the opening. When power is out on Chexit device, E996L-FSE trim will remain locked to ...:
Does Von Duprin offer an exit device for exterior use?
Resolution:
Most Panic devices are not designed for exterior applications. As with any mechanical device, exposure to the elements may affect the operation and life of the device and/or finish an...:
Can a Von Duprin 3' pushpad exit device be converted to a 4' device in the field?
Resolution:
A 3' exit device cannot be converted to a 4' exit device. You will need to replace the 3' device with a 4'. Conversely, a 4' device cannot be converted to a 3' device. Converting these exit de...: