Von Duprin 98/99 and 98/99XP Rim/SVR/CVR(steel door only)/Mortise exit devices are compatible with AD200, AD250, AD300, AD400, AD401-993 exit trims.
Von Duprin 22/22F Rim/SVR exit devices are compatible with AD200 and AD250-993 exit trims.
Falcon 25 Rim exit device is compatible with AD200 and AD250-993 exit trims.
To add the bottom rod and latches on 8827LBR it requires Bottom Rod Kit part #050455-XX 8827 Rod Guide Kit part #50482-XX 8827 LR Bottom Latch Kit W/Cover part #050467-XX 304L Bottom Strike
PN33/35/98/99 Pneumatic exit devices are not usually used with RX or LX switches since the Pneumatic PN device is used instead EL to eliminate the electric from the device.
The Falcon Monarch 18-R-EO device can be converted in the field to the 18-R-L by purchasing three parts. The following items are required to convert the device.  812L or 816L lever tri...
The 5 pound force requirement is in reference to the maximum force to swing the door, not the maximum force allowed to unlatch the exit device.  Maximum allowed force to retract the Von D...
The E996L-FSE trim is needed if the application requires fail-secure operation from the trim side of the opening. When power is out on Chexit device, E996L-FSE trim will remain locked to ...
Panic devices are not design for exterior application. As with any mechanical device, exposure to the elements may affect the operation and life of the device and/or finish and may void&nbs...
Water and electricity do not mix.  Von Duprin electrified devices can NOT be used in an exterior environment.
A 3' exit device can not be modified to a 4' exit device. You will need to replace the device with a 4' one.