Does Von Duprin offer an exit device for exterior use?
Resolution:
Most Panic devices are not designed for exterior applications. As with any mechanical device, exposure to the elements may affect the operation and life of the device and/or finish an...:
Will the 6300 electric strike work with 88-F or the 88 rim panic?
Resolution:
Von Duprin 6300 electric strike will operate with 88 rim but not 88F fire rated exit devices.:
RIM PANIC DEVICE
Resolution:
RPD; Panic Exit:
Will an ALK sound when the exterior trim is used to enter from the pull side?
Resolution:
The ALK exit alarm will sound when the exterior trim is used to enter from pull side without using access control when an LX latch bolt monitor switch is used instead of RX push bar monitor switch.:
What strike do I specify with the 9975 device on a pair of 1 3/4" thick doors with a flat overlapping astragal mounting on the exterior of the active door?
Resolution:
Use the 575-2 strike with 9975 device on a pair of 1 3/4" thick doors with overlapping astragal mounting on the exterior of the active door. The strike lip has been cut off to eliminate any interfe...:
Von Duprin electrified mullions and handing details.
Resolution: