Question
Answer
Is there a template that shows where to drill the hole for E/EL/SS/RX/LX/CX wires?
Resolution:
The hole should be drilled in the field once the end cap is located on the door. It is a 5/8" hole, that is located 5/16" from the end of the mechanism case. See installation instruction of t...:
Does the ND lock have an RX option?
Resolution:
The ND lock is available with an RX option:When ordering a complete ND lock specify RX when the request to exit (RX) switch is required.The ND80EL, ND80EU, ND96EL, ND96EU, ND12EL, ND12EU electrifie...:
What are the 3 wires on the Falcon AE switch?
Resolution:
For 24/25 devices per instructions : Violet - Normally Open Black - Common Gray - Normally Closed:
What is the wire gauge on the motor driven L9000 mortise locks?
Resolution:
Supply wires - 24AWGRX wires - 20AWGLX wires - 20 AWG:
What size wire and run is recommended when using a PS914-2RS?
Resolution: