pushbutton lock with exit device
”
RELATED FAQS
Question
Answer
Why can't I LINK my AD-Series lock?
Resolution:
4. PIM400/AD400 COM400 plug could be damaged! The small pins in the Main PCB board connection for the RF COMM board can get bent during installation of the RF COM400 board. If the PINs are be...:
What causes the error "Device does not support this action - E802" when I'm coupling an AD lock?
Resolution:
In order to properly couple, the interior pushbutton must be held down while tapping the SW1 (tamper switch) three times. This will enable the lock to couple to the HHD.:
Why doesn't the AD-Series-Exit Device communicate with the Hand Held Device after rehanding the lockset?
Resolution:
During the rehanding of an AD-Series Exit (993) device or the rehanding of a CO-Series Exit (993) device it is possible for the customer to damage the 5-inch pcba by using the wrong screws. D...:
Can the 5100 electric strike be used with a mortise exit device?
Resolution:
The 5100 electric strikes are for use with cylindrical locks only. Instead use the following:6211 electric strike is used with mortise lock without deadbolt on a new single door, hollow ...:
How do I change the function of the Von Duprin 7500 mortise lock from Lever ( classroom ) to NL ( night latch )?
Resolution:
To convert the Von Duprin 9975L to 9975NL exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL screw on 7500 mortise lock counter clo...:
When are Panic Devices required?
Resolution:
The use of Panic Hardware and/or Fire Exit Hardware is required by the International Building Code (IBC) and NFPA 101 – The Life Safety Code, depending on which code and which edition of the code i...: