PREP FOR LEAD LINING FRAME

RELATED FAQS

Question
Answer
Not specifically for lead lined doors.  But the standard hinges should work and not hit the leadlining in the door.  Since standard lead layers vary, check with door manufacturer and hinge template.
The door template L1 states: "Lead Lining: When L9000-Series or L400-Series locks are ordered with lead lining, add 1/8" to the width of the mortise cut-out on the lock case cover side of installa...
Lead lined frames are intended for use in the X-ray Room locations in Health Care facilities. Frames are provided by Steelcraft prepped as follows:  Frames are supplied knock-down (KD). Fram...
Radiation, Lead Lined
XL11-515 is an option for lead lining on the L9000 series mortise locks. XL12-216 is an option for lead lining on the L400 mortise locks.
Lead lining is not needed, since the channel or through bolt is solid and the x-rays will not penetrate the solid metal.
The Locknetics 9100 series electric strikes are replaced with Von Duprin 6211 and 6210 electric strikes.   6211 is used for new and 6210 is for existing application. For existing applic...